HomeMy WebLinkAbout8/11/2021 - Planning Commission - Agenda -RegularPlanning Commission Meeting
AGENDA
Wednesday, August 11, 2021, 6:00 P M
Work S ess ion, 6:00P M C o uncil C hambers C o nferenc e R o om
R egular S es s io n 7:00P M C ounc il C hamb ers, C ity Hall, 114 North Broad S treet, S alem, Virginia 24153
WORK SE SSI ON
1.C all to Order
2.New Business
A.Discussion item from the September meeting
Rezoning of 405 Kimball Avenue, Tax Map # 235-1-2 from RMF, Residential Multi-Family
District with condition to RMF, Residential Multi-Family District without conditions.
B.Discussion items from the August Meeting
Discussion of items from the August 11, 2021, regular session agenda.
3.Adjournment
RE GU L AR SE S SI ON
1.C all to Order
2.Pledge of Allegiance
3.C onsent Agenda
A.Minutes
C onsider acceptance of the minutes from the J uly 14, 2021, work session and regular meeting.
4.New Business
A.Amendment to the Zoning Ordinance
Hold public hearing to consider the request of Layman Candy C ompany, Inc., contract purchasers,
and Lewis-Gale Medical Center, LLC , property owner, for rezoning a portion of the property
located at 2105 Apperson Drive (Tax Map # 281-1-2) from BC D Business Commerce District to
LM Light Manufacturing District.
B.Amendment to the Zoning Ordinance
Hold public hearing to consider the request of Roanoke College Trustees, property owner, for
rezoning a portion of the property located at 232 North Broad Street (Tax Map # 87-7-7), from
C UD C ollege and University District to RSF Residential Single-Family District.
C .T he Village at North Mill P hase F our
C onsider the request for preliminary and final approval of proposed subdivision plan and plat filed
by RFC2017 Land, LLC, property owner/developer, for a 7.767-acre tract known as T he Village
at North Mill Phase Four.
D.Calhoun Townhomes
C onsider the request for preliminary and final approval of proposed subdivision plan and plat filed
by Virginia Valley Properties, LLC , property owner/developer, for a 0.72-acre tract known as the
C alhoun Townhomes.
E.Salem Historic Registry
C onsider petition from J A SS Properties, Inc., for inclusion in the Salem Historic Registry of the
property located at 401 South market Street (Tax Map # 145-10-2).
5.Adjournment
C ity C ouncil meeting, August 23, 2021, 6:30 p.m.
Council Chambers, City Hall, 114 North Broad Street
Item # WS 2A
Meeting Date: 8-11-21
AT WORK SESSION OF THE PLANNING COMMISSION OF THE CITY OF SALEM,
VIRGINIA HELD AT COUNCIL CHAMBERS, CITY HALL, 114 NORTH BROAD STREET,
SALEM, VIRGINIA
AGENDA ITEM: Amendment to the Zoning Ordinance
Discuss Rezoning of 405 Kimball Avenue, Tax Map # 235-1-2
from RMF, Residential Multi-Family District with condition to
RMF, Residential Multi-Family District without conditions.
SUBMITTED BY: Benjamin W. Tripp, AICP, CEcD, City Planner
SUMMARY OF INFORMATION:
Zoning: RMF Residential Multi-Family, with conditions
Future Land Use Plan Designation: Resiential
Existing Use: Vacant
Proposed Use: Townhouse
The subject property consists of a single parcel of approximately 0.8 acres, located along the
north side of Kimball Avenue, east of the intersection with Pyrtle Drive. It is was commonly
known as the site of “Mount Regis” before it was destroyed by fire. The property is currently
vacant.
SUMMARY OF PROPOSED CHANGES;
The applicant is requesting the following condition be removed:
The only R-4, Residential District, use which will be made of the property will be as a human care
facility.
Doing so will allow the construction of townhomes by right.
August 2, 2021
Mr. Jay Taliaferro
City Manager - City of Salem
21 South Bruffey Street
Salem, VA 24153
RE: 405 Kimball Avenue – Salem, VA 24153
Balzer and Associates, Inc. Job # 04210054.00
Rezoning Request
Dear Mr. Taliaferro,
PHC of Virginia, Inc. (Property Owner) and Salem Building Supply, Inc. (Contract Purchaser) are
providing official application, supporting documents, and associated fees required to request a removal of
an existing proffered condition on tax parcel 235-1-2. The zoning designation will remain the same as
Residential Multi-Family District (RMF). The removal of the existing proffered condition will allow the
site to be developed as townhomes under the current zoning district.
Project Narrative & Existing Conditions:
The existing parcel is currently vacant and has been since the Mount Regis facility was destroyed by fire in
2016. The Mount Regis facility use of “Human Care Facility” is the only allowable use per the current
proffered condition. Salem Building Supply, Inc. intends to develop the site into seven (7) townhomes with
associated improvements. This use is complementary to the existing mix of single family residential, two-
family dwellings, and multi-family development in the area. These residential townhomes will compliment
the surrounding area while providing additional opportunities for housing within the City of Salem.
See attached civil exhibit plan – “Zoning Exhibit – Exhibit A” dated 8/3/2021 for the proposed townhouse
buildable area. Exhibit B and B1 have been provided offering an example of the townhouse elevations
from Kimball Avenue. The existing parcel is approximately 0.82 acres and is bounded by the public rights-
of-way of Kimball Avenue to the South, RSF zoned property to the west, north, and east. The parcel
generally drains from south to north.
Buffers
A twenty five (25’) buffer consisting of evergreen trees will provided between the existing adjacent RSF
parcels and the existing RMF zoning (subject parcel).
Comprehensive Development Plan & Summary:
This project is in conformance with many of the Goals and Objectives defined in the City of Salem’s
Comprehensive Plan. This project is sensitive to the existing surrounding properties by utilizing a vacant
property for an appropriate use to match surrounding land uses. This project provides an excellent
opportunity to the City of Salem to gain additional residential property in a location of high demand.
Sincerely,
Benjamin T. Crew
Associate
N/F
PHC OF VIRGINIA INC
TAX#: 235-1-2
LOT SIZE: 0.82 AC.
ZONING: RMF
N/F
CITY OF SALEM
TAX#: 216-4-1
LOT SIZE: 21.09 AC.
ZONING: RSF
N/F
PINELLO LYNDA W
TAX#: 235-1-1
LOT SIZE: 0.204 AC.
ZONING: RSF PROPOSED TOWNHOUSE
DEVELOPMENT
±7 UNITS
25' B
U
F
F
E
R
25
'
B
U
F
F
E
R
PROJECT NO.
REVISIONS
SCALE
DATE
CHECKED BY
DESIGNED BY
DRAWN BY
www.balzer.cc
Roanoke / Richmond
Shenandoah Valley
New River Valley / Lynchburg
P L A N N E R S / A R C H I T E C T S
E N G I N E E R S / S U R V E Y O R S
J:
\
2
1
\
0
0
\
0
4
\
0
4
2
1
0
0
5
4
.
0
0
K
I
M
B
A
L
L
A
V
E
N
U
E
T
O
W
N
H
O
M
E
S
\
C
I
V
I
L
\
d
w
g
\
0
4
2
1
0
0
5
4
R
e
z
o
n
i
n
g
B
a
s
e
_
N
o
U
n
i
t
s
.
d
w
g
P
L
O
T
T
E
D
:
8/
3
/
2
0
2
1
9
:
0
9
:
5
8
A
M
1208 Corporate Circle
Roanoke, VA 24018
540.772.9580
SMD
BTC
BTC
8/3/2021
1" = 20'
KI
M
B
A
L
L
A
V
E
N
U
E
T
O
W
N
H
O
M
E
S
ZO
N
I
N
G
E
X
H
I
B
I
T
40
5
K
I
M
B
A
L
L
A
V
E
N
U
E
CI
T
Y
O
F
S
A
L
E
M
EX-A
04210054.00
PRE
L
I
M
I
N
A
R
Y
LEGAL DESCRIPTION:
KIMBALL AVENUE TOWNHOUSE
TAX MAP NUMBER 235-1-2
BEGINNING AT A POINT ON THE NORTH LINE OF KIMBALL AVENUE;
THENCE N 15°37'00" E A DISTANCE OF 165.00' TO A POINT ON THE SOUTH LINE OF AN UNIMPROVED
STREET;
THENCE S 57°44'05" E A DISTANCE OF 247.30' TO A POINT;
THENCE WITH A CURVE TURNING TO THE RIGHT WITH AN ARC LENGTH OF 127.77', WITH A RADIUS OF
101.02', WITH A CHORD BEARING OF S 21°30'00" E, WITH A CHORD LENGTH OF 119.42' TO A POINT ON
THE NORTH LINE OF KIMBALL AVENUE;
THENCE N 74°11'00" W A DISTANCE OF 309.00' TO A POINT WHICH IS THE POINT OF BEGINNING.
HAVING AN AREA OF 35,809 SQUARE FEET, 0.822 ACRE
UNAPPROVED MINUTES
PLANNING COMMISSION WORK SESSION
July 14, 2021
A work session of the Planning Commission of the City of Salem, Virginia,
was held in Council Chambers Conference Room, City Hall, 114 North Broad
Street, at 6:00 p.m., on July 14, 2021, there being present the members of said
Commission, to wit: Vicki G. Daulton, Chair; Denise P. King, Vice Chair, Reid A.
Garst II, N. Jackson Beamer, and Neil L. Conner; together with James E.
Taliaferro, II, City Manager and Executive Secretary, ex officio member of said
Commission; Charles E. Van Allman, Jr., Director of Community Development,
Mary Ellen Wines, Zoning Administrator; Benjamin W. Tripp, City Planner; and
Jim H. Guynn, Jr. City Attorney; and the following business was transacted:
Whereas Chair Daulton called the meeting to order at 6:02p.m. and
reported that this date, place, and time had been set in order for the Commission
to hold a work session; and
In re: Hold public hearing to consider the request of the Salem
Historical Society, property owner, for rezoning the
property located at 1936 West Main Street (Tax Map #
138-2-7) from CBD Community Business District with
proffered conditions to CBD Community Business District
without conditions.
Whereas staff noted the following: the subject property consists of a single
parcel of approximately 9.4 acres, located along the south side of West Main
Street, east of the intersection with Wildwood Road. It is occupied by a
historically designated two-story home.
Whereas Commissioner Garst inquired if CBD was the correct zoning district
for this property; and
Whereas, Mr. Tripp responded affirmatively, that the Society had wanted to
have the flexibility to have residential on the 2nd floor; and
Whereas, a full and lengthy discussion was held regarding the request
of the Salem Historical Society, property owner, for rezoning the property
located at 1936 West Main Street (Tax Map # 138-2-7) from CBD Community
Business District with proffered conditions to CBD Community Business
District without conditions; and
In re: Hold public hearing to consider the request of Property
Catalyst Group, Inc., applicant, and Layman Candy
Company, Inc., property owner, for rezoning the property
2
located at 1637 East Main Street (Tax Map #77-3-13)
from LM Light Manufacturing with proffered conditions, to
HBD Highway Business District without conditions; and
Hold public hearing to consider the request of Property
Catalyst Group, Inc., applicant, and Layman Candy
Company, Inc., property owner, for rezoning the property
located at 23 Dalewood Avenue (Tax Map #77-3-12) from
HBD Highway Business District with proffered conditions,
to HBD Highway Business District without conditions; and
Hold public hearing to consider the request of Property
Catalyst Group, Inc., applicant and Layman Candy
Company, Inc. and George W. Givens Jr. & Susan K.
Givens, property owners, for the issuance of a Special
Exception Permit to allow personal storage on the
properties located at 1637 & 1641-1647 East Main Street,
and 11, 15, & 23 Dalewood Avenue (Tax Map #s 77-3-13,
77-3-16, 77-3-15, 77-3-14, and 77-3-12).
Whereas staff noted the following: Items 4B, 4C, and 4D are all
connected. There is only one staff report to cover the entire project, but
there are three separate requests which must be voted on; and
Whereas staff explained that the subject property consists of five
parcels totaling approximately two acres, located at the northeast corner of
Electric Road and East Main Street. They are occupied by a large L shaped
warehouse, parking areas, two single family homes, and a two-story
commercial structure. Tax Map 77-3-12 and 77-3-13 have the following
conditions: The following conditions voluntarily proffered shall apply in
addition to the regulations contained in Chapter 32 of The Code of the city of
Salem: 1. A fifty-foot setback will be observed from the centerline of
Dalewood Avenue should the rental property be moved for future building
expansion. 2. Proper screening will be provided on the north side of the
property. SUMMARY OF PROPOSED CHANGES; The applicant is requesting the
LM zoned property be rezoned to HBD without conditions (Item B), that the
HBD property with conditions have its conditions removed (Item C), and that
a Special Exception Permit be granted in order to allow the Personal Storage
use on all of the properties (Item D). The existing buildings would be
demolished, and a new 99,000 sq ft three story self-storage building would be
constructed on the site; and
Whereas staff added that the petitioners had submitted proffered
conditions in relation to items B and C. Proffer 1. The property will be
3
developed in substantial conformance with the conceptual site plan
prepared by Balzer and Associates, Inc. entitled "Layman Candy Company"
dated June 7, 2021, subject to any changes to access that may be required
by the City of Salem and the Virginia Department of Transportation during the
site plan review process. Proffer 2. The building will be developed in
substantial conformance with the provided architectural perspective rendering
indicated as Exhibit B and dated July 6, 2021; and
Whereas the updated elevation drawing was presented to the
Commission; and
Whereas staff explained the procedure for the applicants to gain access
onto Electric Road; and
Whereas, a full and lengthy discussion was held regarding the request
for rezoning the property located at 1637 East Main Street (Tax Map #77-3-
13) from LM Light Manufacturing with proffered conditions, to HBD Highway
Business District without conditions, rezoning the property located at 23
Dalewood Avenue (Tax Map #77-3-12) from HBD Highway Business District
with proffered conditions, to HBD Highway Business District without
conditions, and the issuance of a Special Exception Permit to allow personal
storage on the properties located at 1637 & 1641-1647 East Main Street, and
11, 15, & 23 Dalewood Avenue (Tax Map #s 77-3-13, 77-3-16, 77-3-15, 77-
3-14, and 77-3-12).
Whereas staff noted the following: The plat and plan for the Calhoun
Townhomes and the Village at North Mill Phase Four would appear on the agenda
of a future meeting. Staff briefly described each proposal.
Whereas a discussion was held regarding the continuation of the
formation of by-laws for the Commission; and
THEREUPON, the Commission took no action at this work session.
There being no further business to come before the Commission, the work
session was adjourned at 6:54 p.m.
Chair
Executive Secretary
Planni ng Commi ssi on Meeti ng
M INUTES
Wednesday, July 14, 2021, 7:00 P M
Council Chambers, City Hall, 114 North Broad Street, Salem, Virginia
1.C all to Order
2.Pledge of Allegiance
3.C onsent Agenda
A.Minutes
Consider acceptance of the minutes from the J une 16, 2021, work session and
regular meeting.
Reid Garst motioned C onsider acceptance of the minutes from the J une 16, 2021,
work session and regular meetnig.. J ackson Beamer seconded the motion.
Ayes: Beamer, Conner, Daulton, Garst, King
4.New Business
A.Amendment to the Zoning Ordinance
Hold public hearing to consider the request of the Salem Historical Society,
property owner, for rezoning the property located at 1936 West Main Street (Tax
Map # 138-2-7) from C BD C ommunity Business District with proffered conditions
to C BD C ommunity Business District without conditions.
Staff noted the following:
T he subject property consists of a single parcel of approximately 9.4 acres, located
along the south side of West Main Street, east of the intersection with Wildwood
Road. It is occupied by a historically designated two-story home.
Previously, the owner of the property requested the zoning be changed to C BD with
proffered conditions to allow a restaurant. T hey are now requesting those conditions
be changed in order to allow more flexibility for the property, and to allow “Glow
Healing Arts” as a tenant.
Lisa Bain, President of the Board for Salem Museum and Historical Society,
appeared before the C ommission; she stated that the Salem Museum and Historical
Society owns Preston Place that used to be the White Oak Tea Tavern, but due to
the pandemic the business went out of business. T he Historical Society has been
working to get a new tenant for the property, and has a new tenant, Glow Healing
Arts. T he property currently isn't zoned for personal services, which is why the
request to remove the conditions, which would allow personal services to be an
acceptable tenant for the property.
Susan Menee, 2127 Laurel Woods Drive, Salem, past president of the Salem
Museum and Historical Society, appeared before C ommission and stated that they
are excited and hopeful that the change can be made; and feel that Glow Healing
will be a much more beautiful and appropriate and more gentler use of the space; it
will also allow them to preserve the historical use of the property.
J essee C antelope, Meredith Novack's partner who is the current tenant of the
property, who resides at 511 Tennessee Avenue, appeared before the C ommission.
He stated that Ms. Novack is a little under the weather and could not attend the
meeting. He further stated that Glow Healing provides spa-type services--massage,
reiki, chiropractic and need to make sure they have approval to operate that type of
business there.
Vice C hair King questioned if only the first floor would be occupied, or would the
second floor be occupied as well, and the office hours of the business.
Mr. Novack stated that the second floor would be occupied as well as the first
floor. T he office hours are standardly 9 a.m. to 5 p.m., but will sometimes vary
depending on the practitioners. T he chiropractor will be the only practitioner on the
first floor, and the second floor will be the majority of the practitioners. He stated
that community services are offered to art classes and groups, etc. T he three rooms
downstairs will be primarily gift and sales, and functions.
Member Beamer questioned if the hours were Monday through Friday, or weekends
as well.
Mr. Novack stated that the hours are standardly Monday through Friday, but often
things are done on the weekend. Weekends will vary depending on the event or
sometimes practitioners' schedules. Often yoga and massage are done on weekends.
Member Garst questioned if there will be any outdoor use on the property.
Mr. Novack stated that some things will be done outside. T hey had a picnic
recently and invited members of the Historical Society. No major functions will be
done outside. Yoga practice might be done outside on the lawn or something
similar.
C hair Daulton questioned the number of people who would be on the property at
one time.
Mr. Novack stated that there typically isn't that many people present. If every
practitioner had someone, there would possibly be 10 people; the nights with groups
or yoga, there would be 10-15 people at the most.
No other person(s) appeared before the Commission.
Neil Conner motioned to recommend the request of the Salem Historical Society,
property owner, for rezoning the property located at 1936 West Main Street (Tax
Map #138-2-7) from C BD Community Business District with proffered conditions
to C BD Community Business District without conditions.. J ackson Beamer
seconded the motion.
Ayes: Beamer, Conner, Daulton, Garst, King
B.Amendment to the Zoning Ordinance
Hold public hearing to consider the request of Property C atalyst Group, Inc.,
applicant, and Layman Candy Company, Inc., property owner, for rezoning the
property located at 1637 East Main Street (Tax Map #77-3-13) from LM Light
Manufacturing with proffered conditions, to HBD Highway Business District
without conditions.
It was noted that one public hearing will be held for Items 4B, 4C , and 4D.
Staff noted the following:
T he subject property consists of five parcels totaling approximately two acres,
located at the northeast corner of Electric Road and East Main Street. T hey are
occupied by a large L-shaped warehouse, parking areas, two single family homes,
and a two story commercial structure.
Tax Map 77-3-12 and 77-3-13 have the following conditions:
T he following conditions voluntarily proffered shall apply in addition to
the regulations contained in C hapter 32 of T he Code of the city of Salem:
1. A fifty-foot setback will be observed from the centerline of Dalewood Avenue
should the rental property be moved for future building expansion.
2. Proper screening will be provided on the north side of the property.
SUMMA RY O F PRO PO SED C HA N G ES;
T he applicant is requesting the LM zoned property be rezoned to HBD without
conditions
(Item B), that the HBD property with conditions have its conditions removed (Item
C ), and
that a Special Exception Permit be granted in order to allow the Personal Storage
use on all
of the properties (Item D). T he existing buildings would be demolished, and a new
99,000
sq ft three story self-storage building would be constructed on the site.
Note that though there is only one staff report, there are three separate requests
which must
be voted on.
J oseph T hompson, 26 Carriage Lane, Troutville, VA, appeared before the
C ommission and stated that the project has three items--the rezoning is to cleanup
the overall corner and to have everything on the same page to move forward with the
Special Exception Permit. He further stated that he has done three projects similar
to this in the valley--off Plantation Road, a K-Mart conversion on Franklin Road, as
well as, their first project which has been expanded once, located on Dale Avenue in
Southeast Roanoke. T he projects are extremely well done; the facades are similar
to the facade that was presented with the rendering in the packet. High-quality
materials are used like what is used for office buildings and apartment buildings that
have been recently constructed. It is not the old metal buildings of the past. T he
project will change what is there today, which has gone way beyond its useful life,
and take it to a more modern look. T he corner has been a challenge corner and
there is only so much intensity of traffic allowed. He is requesting that the
conditions be removed as they aren't relevant; the manufacturing facility will be
removed, which could be used for a much more intensive use than personal storage;
the dilapadated commercial structures will be removed, as well as the billboard that
sits atop of the distribution/manufacturing facility. He also stated that a buffer is
currently non-existent to the residential area. He plans to place a new, modern
evergreen Type B 15-foot buffer and have a drive aisle, and then have a building.
T he site will also have adequate landscaping as required in modern construction and
will be a part of their marketing strategy.
A discussion was held regarding the type of storage facility--more like a room to
store things in rather than a building; will have an elevator, security codes to access
facility, security cameras, lighting inside 24/7 that is sensored throughout, but not
24/7 access. Individual as well as some smaller commercial (i.e. pharmaceutical
representatives) are expected to use the facility.
Vice C hair King questioned if the canopy would be the only entrance to the
building.
Mr. T hompson stated there would also be an office at the front corner with a
separate entrance.
Member Beamer questioned what hours the facility would be open.
Mr. T hompson stated the hours would be 6:00 a.m. to 9:00 p.m. He noted that
insurance is required for commercial-type people to use the facility, and typically
10-foot trucks and personal vehicles is what is used to bring the items to the
facility. No food will be stored in the rooms.
A discussion was held regarding lighting on the grounds. T he lighting pointed
toward the residential area will be LED with shields.
A discussion was held regarding the buffer to be placed on the property to separate
it from the resential area.
Member Garst questioned if all access points will have a gate.
Mr. T hompson stated that Access Points 1 and 3 will have a gate to separate them
and there will be a no thru traffic sign placed on the property to help prevent a cut-
thru from Dalewood Avenue to Electric Road.
Vice C hair King questioned if there would be an on-site manager on the property at
all times.
Mr. T hompson stated that there would be an on-site manager at the facility during
hours, and the facility will be heavily-cameraed for security purposes.
A discussion was held regarding the size of the rental space and number of units
available for rent. T here will be approximately 73,000 s.f. of rental space with
approximately 600 units available to rent. T here will be a manager and two part-
time managers, plus maintenance will be shared among facilities. T he units will
range in size from 5'x5' to 10'x30'. T he structure will be approximately 36' high.
Mr. T hompson stated that he is the contract purchaser of the property.
Member C onner questioned if the project will work if VD O T does not grant the
ingress/egress from Electric Road.
Mr. T hompson stated that he feels there will be good success with the request based
upon initial conversations, and the fact that the C ity of Salem owns and maintains
the right-of-way and has expressed its support. If VD O T says to do it differently,
then he would have to go back to the drawing board.
A discussion was held regarding the access to the site from Electric Road.
Member Beamer noted that the alley would have to be vacated and questioned if it
had to go through the viewer process.
T he Director of Community Development confirmed that it would have to go
through the process in order to be vacated.
No other person(s) appeared related to the item.
Mr. Tripp, C ity Planner, noted that the applicant has agreed to proffer the following
conditions as they apply to the rezoning requests for Tax Map #s 77-3-13, 77-3-12,
77-3-14, 77-3-15, and 77-3-16: 1.) the property will be developed in substantial
conformance with the conceptual site plan prepared by Balzer and Associates
entitled, "Layman Candy Company" dated J une 7, 2021, subject to any changes to
access that may be required by the City of Salem and the Virginia Department of
Transportation during the site plan review process; and 2.) the building will be
developed in substantial conformance with the provided architectural perspective
rendering indicated as Exibit B dated J uly 6, 2021.
Reid Garst motioned to recommend the request of Property C atalyst Group, Inc.,
applicant, and Layman C andy C ompany, Inc., property owner, for rezoning the
property located at 1637 East Main Street (Tax Map #77-3-13) from LM Light
Manufacturing with proffered conditions, to HBD Highway Business District with
conditions.. Neil Conner seconded the motion.
Ayes: Beamer, Conner, Daulton, Garst, King
C .Amendment to the Zoning Ordinance
Hold public hearing to consider the request of Property C atalyst Group, Inc.,
applicant, and Layman Candy Company, Inc., property owner, for rezoning the
property located at 23 Dalewood Avenue (Tax Map #77-3-12) from HBD Highway
Business District with proffered conditions, to HBD Highway Business District
without conditions.
Reid Garst motioned to recommend the request of Property C atalyst Group, Inc.,
applicant, and Layman C andy C ompany, Inc., property owner, for rezoning the
proeprty located at 23 Dalewood Avenue (Tax Map #77-3-12) from HBD Highway
Business District with proffered conditions, to HBD Highway Business District
with conditions.. Neil C onner seconded the motion.
Ayes: Beamer, Conner, Daulton, Garst, King
D.Special Exception P ermit
Hold public hearing to consider the request of Property C atalyst Group, Inc.,
applicant and Layman C andy C ompany, Inc. and George W. Givens J r. & Susan K.
Givens, property owners, for the issuance of a Special Exception Permit to allow
personal storage on the properties located at 1637 & 1641-1647 East Main Street,
and 11, 15, & 23 Dalewood Avenue (Tax Map #s 77-3-13, 77-3-16, 77-3-15, 77-3-
14, and 77-3-12).
T he conditions for the Special Exception Permit are as follows: 1.) contingent on
the C ity vacating the right-of-way between Tax Parcel 77-3-12 and 77-3-14; 2.)
contingent on the C ity and VD O T allowing access to the site from Electric Road
north of East Main Street; 3.) the property will be developed in substantial
conformance with the conceptual site plan prepared by Balzer and Associates
entitled, "Layman Candy Company" dated J une 7, 2021, subject to any changes to
access that may be required by the City of Salem and the Virginia Department of
Transportation during the site plan review process; 4.) the building will be
developed in substantial conformance with the provided architectural perspective
rendering indicated as Exibit B dated J uly 6, 2021; and 5.) the Special Exception
Permit is subject to revocation if the project does not have all permits within three
(3) years.
Reid Garst motioned to recommend the request of Property C atalyst Group, Inc.,
applicant, and Layman C andy C ompany, Inc. and George W. Givens, J r & Susan K.
Givens, property owners, for the issuance of a Special Exception permit to allow
personal storage on the properties located at 1637 & 1641-1647 East Main Street,
and 11, 15, & 23 Dalewood Avenue (Tax Map #s 77-3-13, 77-3-16, 77-3-15, 77-3-
14, and 77-3-12) with conditions.. Neil C onner seconded the motion.
Ayes: Beamer, Conner, Daulton, Garst, King
5.Adjournment
Neil Conner motioned Meeting adjourned at 7:41 p.m.. J ackson Beamer seconded
the motion.
Ayes: Beamer, Conner, Daulton, Garst, King
Work Session, Wednesday, J uly 14, 2021, 6:00 p.m.
C ouncil C hambers C onference Room, C ity Hall
C ity Council meeting, J uly 26, 2021, 6:30 p.m.
C ouncil C hambers, C ity Hall, 114 North Broad Street
Item # 4A
Meeting Date: 7-14-21
AT A REGULAR MEETING OF THE PLANNING COMMISSION OF THE CITY OF SALEM,
VIRGINIA HELD AT COUNCIL CHAMBERS, CITY HALL, 114 NORTH BROAD STREET,
SALEM, VIRGINIA
AGENDA ITEM: Amendment to the Zoning Ordinance
Hold public hearing to consider the request of Layman Candy
Company, Inc., contract purchasers, and Lewis-Gale Medical
Center, LLC, property owner, for rezoning a portion of the
property located at 2105 Apperson Drive (Tax Map # 281-1-2)
from BCD Business Commerce District to LM Light
Manufacturing District. Advertised in the July 29 and August 5,
2021 issues of the Salem Times-Register.
SUBMITTED BY: Benjamin W. Tripp, AICP, CEcD, City Planner
SUMMARY OF INFORMATION:
Zoning: BCD Business Commerce District
Future Land Use Plan Designation: Commercial
Existing Use: Vacant, Storage and Warehousing
Proposed Use: Warehousing and Distribution
The subject property consists of a single parcel of approximately 9.4 acres, located along the
north side of Apperson Drive, adjacent to the Eastern City Limits. It is occupied by a single
large building that was part of the original shopping center, but which was most recently used
as offices, a technical college, and as storage. This building is being subdividing off
separately, so the request only applies to it.
SUMMARY OF PROPOSED CHANGES;
The owner of the property is requesting that the large building and its tract be rezoned to
Light Manufacturing in order to allow the relocation and growth of their warehousing and
distribution business. The applicant states that this new location will enable them to add
product lines, increase sales significantly, and that they intend to add one hundred new
employees in the next five years as they grow.
FISCAL IMPACT:
Allowing an existing business to expand and to hire a large number of employees will produce
a positive fiscal impact.
STAFF RECOMMENDATION:
Staff recommends approval.
1. Applicant(s):
PETITION FOR ZONING AMENDMENT (REZONING)
City of Salem Community Development Departm ent
----senjamin W~ Tripp, AIC P: City Planner
Email : btriDe@salemva .gov
Telephone: 540-375-3032
Layman Candy Co, Inc.
P.O. Box 1015 Salem, VA 24153
2. Legal Owner(s) of property requested to be rezoned:
Lewis-Gale Medical Center, LLC c/o Real Estate Department
3. Location of Property:
Address : 2105 Apperson Drive Sa lem, VA 24153
Subdivision: Plat Book 8. Page 25 . Slide 160
Official Tax Map Number: Portion of Tax Parcel: 281-1-2
4. Characteristics of Property:
Size (Acreage): 9.42 +/-Acres
Deed Restrictions: .....!..!n/~aL-.-------------------------
Present Use : Currently Vacant I Previous Business School
5. Zoning Classificat ion:
Present Zoning: . BCD -Business Commerce District
Proposed Zoning : LM -Light Manufacturing
Land Use Des ignation : Future Land Use Map Indicates as Commercial
6. Reason(s) for Rezoning Request (Including proposed use):
See Attached Narrative
7. Agent(s) or representative(s) of property owner(s): (Specify interest)
Balzer & Associates, Inc. c/o Ben Crew
Mailing Address : 1208 Corporate Circle Roanoke. VA 24018
Telephone Number: ....:5!.!:4:u!.!. . .1-1,,,1-...w.w.w.11t..-----------------~----
8. Affidavit:
A. The unders igned person certifies that this petition and the forego ing answers, statements, and other information
herewith submitted are in all respects true and correct to the best of their knowledge and belief, Also, the
pet itioner understands that a "N~tice of Zoning Request" sign will be posted on the property by the City . £ . ~~~.,4-L--~~---Date : 4;/XJ/,;<IJ.:t I
Applicant Phone N
Owner Signature: ..g__.£.µ~:-=--~'-'---~c...L.:------Date : Ct.> ~ :1-t(
0 I t t . icho s L Paul, Vice Pre sident of Lewis-Ga le Medical Center, LLC Wner n eres In rO rty.__..1"1.l::00..1J1.%,,..owwine...,rs1.111ohipui.in .... ter""'es.._t -----------------
Owne r Maili ng Address: One Park Plaza . Nashville. TN 37203 • Attn · vice presjdeot. Real Estate
Owner Telephone Number: -'=e1=sl.-344-..;..;s=9a=2'---------------------
July 1, 2021
Mr. Jay Taliaferro
City Manager - City of Salem
21 South Bruffey Street
Salem, VA 24153
RE: 2105 Apperson Drive – Salem, VA 24153
Portion of Tax Parcel 281-1-2
Rezoning Request
Dear Mr. Taliaferro,
Layman Candy Co. Inc. (Contract Purchaser/Applicant) “Layman” are providing official application,
supporting documents, and associated fees required to request a Rezoning of a portion of tax parcel 281-1-
2, from Business Commerce District (BCD) to Light Manufacturing District (LM). The proposed zoning
will allow for Layman candy Company to relocate within the City of Salem to continue and expand business
operations within a currently vacant and larger facility. This zoning request supports the growth objectives
and business direction outlined below.
Business Update:
The purchase by Layman Candy Company, Inc (DBA Layman Distributing) of 2105 Apperson Drive; Salem,
VA; 24153 (Site) and the subsequent rezoning to Light Manufacturing will have the following impacts on
Layman Candy Company’s business:
• Growth Opportunity – Allow Layman Distributing to expand business through additional capacity
for products carried, services provided, and the employees necessary to sustain business
expansion. Our reported Sales for 2020 were $289,000,000. With the additional capacity gained
with this site, we foresee that we can grow our sales to at least $500,000,000 in the next 5 years
• Service Area – Layman currently service Virginia, North Carolina, and West Virginia. Additional
capacity at Site will allow Layman Distributing to begin servicing Tennessee, Kentucky,
Washington, DC, Maryland, and South Carolina. All these new areas would be serviced out of
Salem, VA Site with satellite operations added in outlying areas as needed
• Expansion through acquisition – Given the recent consolidation in the Convenience Store and Food
Service Distribution industry, Layman has plans to purchase other distributors with owners who are
eager and ready to sell their business to Layman. Layman has a proven track record growth via
acquisition based on Layman’s recent purchases of the following Distributors:
o Patrick Wholesale (Honaker, VA) – 2009
o Sterling Grocery (Princeton, WV – 2018
o Reidsville Grocery (Reidsville, NC) – 2019
• Other Growth opportunities
o Food Service Distribution – Layman receives contact all the time to service more restaurants
in the Roanoke Valley area and beyond, and this site’s additional capacity will allow us
expand our refrigeration capabilities required to bring on additional Food Service Customers
o College and University Distribution – Layman recently have begun servicing several local
colleges, and we see this as a profitable area of growth as these locations require a more
diverse product mix that additional capacity will allow us to stock
• Job Creation – Layman currently employs 110 people of which 80 live in the Roanoke Valley and
surrounding communities. We plan to hire an additional 100 employees in the next 5 years to
support the company’s growth
• Site Improvement – Layman’s plans for this site include demolition of existing interior office space
and conversion to warehousing operations.
• Investment – our plans include investing over 1M into the property that includes design services,
demolition, tenant upfit, modern signage, IT infrastructure, and product warehouse improvements
(Additional fixtures, refrigeration, racking, etc.)
Existing Conditions:
The overall tax map parcel includes multiple buildings with various users and uses. The portion being
requested to be rezoned and indicated on the plat including a large existing building which will be
renovated, large parking lot between the building and Apperson drive, and additional parking/service area
on the northside of the existing building. This is the last parcel to the East prior to crossing the corporate
limits into the City of Roanoke, VA. The property has frontage on the public right of way of Apperson
Drive. Existing utility services are currently in place and they will be upgraded or modified as necessary to
facilitate the new user.
Comprehensive Development Plan & Summary:
This project is in conformance with many of the Goals, Strategies, and Objectives as defined in the City of
Salem’s Comprehensive Plan. This proposed use revitalizes a previously vacant building and converts it to
an active location for a business with a local proven track record. The future land use plan designates this
parcel as commercial. The proposed zoning designation of LM is appropriate for this core building with
the surrounding properties being zoned Highway Business District (HBD) and Heavy Manufacturing
District (HM).
Sincerely,
Benjamin T. Crew
Associate
PRELIMINARY
PRELIMINARY
AG - Agriculture District
BCD - Business Commerce District
CBD - C ommuni ty Business District
CUD - C ollege/U niversity District
DBD - D owntow n Business District
HBD - H ighway Business District
HBD/HM - Highw ay Business/Heavy Manufacturing District
HBD/LM - Highw ay Business/Li ght Manufacturing District
HM - Heavy Manufactur ing Distr ict
LM - Light Manufacturing District
LM/HM - Light M anufacturing/Heavy Manufacturing District
MHP - M anufactured Home Par k District
PUD - Planned Unit District
RB - Residential Business District
RMF - Residential Multi-Family District
RMF/RB - Residential Multi-Family/Residential Business District
RSF - Residential Single Family District
RSF/HBD - Residential Single/Highway Business District
RSF/LM - Residential Single Family/Light Manufacturing
RSF/RB - Residential Single Family/Residential Business District
RSF/RMF - Residential Single Family/Residential Multi-Family District
RSF/TBD - Residential Single Family/Transitional Business District
TBD - Transitional Business District
EXISTING ZONING FUTURE LAND USE
Apperson Drive
(LeeHighway)
HRT of Roanoke,Inc.,PB 8,PG 25
Lewis-GaleBuildingCorp.Plat,PB4,PG82A
A
B
80
30' EASEMENT
City of Salem
City of Roanoke
City of Roanoke
City of Salem
1
2
2.1
3
2-1
165.99
118.09
116.56
29.50
18.83 48.23
29.50317.73
349.45 126.93
150.00
144.80
151.64
254.79
300.00
746.61
922.59
320.00
1183.04
683.11
157.00
933.14
869.29
1
2103
2171
2105-2107-2109-2111-2115-21172119-2121-2131-2141-2155-2157-2159
2041-2043 Apperson Dr
2085 4.924 Ac.
0.948 Ac.
0.4747 Ac.
19.67 Ac.
0 100 20050
Feet±1 inch = 110 fe et AUGUST 2021 PLANNING COMMISSION ITEM 4A2105 APPERSON DR.
CITY OF SALEM
Community Development DepartmentP.O. Box 869Salem, Virginia 24153-0869Phone: (540) 375-3032
Tax Parcel 281-1-2 Buildings Parcels City Limits
Comme rcia l
Dow ntown
Econo mic De velopme nt A rea
In dus trial
In stitutio na l
Mixed Use
Public Pa rks and R ecre atio na l
Reside ntia l
Tran sitio nal
Ta x Parcel 281 -1-2 Bu ildings Pa rce ls City Limits
Item # 4B
Meeting Date: 8-11-21
AT A REGULAR MEETING OF THE PLANNING COMMISSION OF THE CITY OF SALEM,
VIRGINIA HELD AT COUNCIL CHAMBERS, CITY HALL, 114 NORTH BROAD STREET,
SALEM, VIRGINIA
AGENDA ITEM: Amendment to the Zoning Ordinance
Hold public hearing to consider the request of Roanoke College
Trustees, property owner, for rezoning a portion of the property
located at 232 North Broad Street (Tax Map # 87-7-7), from CUD
College and University District to RSF Residential Single-Family
District. Advertised in the July 29 and August 5, 2021 issues of
the Salem Times-Register.
SUBMITTED BY: Benjamin W. Tripp, AICP, CEcD, City Planner
SUMMARY OF INFORMATION:
Zoning: CUD College and University District
Future Land Use Plan Designation: Residential
Existing Use: Vacant, Educational Facilities, College/University
Proposed Use: Single Family Dwelling, Detached
The subject property consists of a single parcel of approximately one acre, located along the
east side of North Broad Street, across the street from Shipman Alley. The use of the property
divides roughly in half: It is occupied by a parking facility, accessed from Red Lane, on the
eastern half, but is vacant on the half fronting on Broad Street.
SUMMARY OF PROPOSED CHANGES;
The applicant is proposing to subdivide off about 1/3rd of the property along North Broad
Street, and is requesting that this portion be rezoned to Residential Single Family in order to
allow the construction of a new single family residence.
STAFF RECOMMENDATION:
Staff recommends approval.
July 1, 2021
Mr. Jay Taliaferro
City Manager - City of Salem
21 South Bruffey Street
Salem, VA 24153
RE: 232 N Broad St – Salem, VA 24153
Balzer and Associates, Inc. Job # 04210036.00
Rezoning Request
Dear Mr. Taliaferro,
Roanoke College Trustees (Property Owner) are providing official application, supporting documents, and
associated fees required to request a Rezoning of a portion of tax parcel 87-7-7, from CUD-
College/University District to RSF-Residential Single Family District. The proposed zoning will allow for
a residential use on a portion of the existing parcel while the remainder of the property can continue to
provide residential parking for Roanoke College.
Project Narrative & Existing Conditions:
A portion of the existing parcel is currently being used to provide residential parking for Roanoke College,
while the remainder of the parcel is vacant. The RSF zoning will allow for the development of a single
family residence along North Broad Street, while maintaining the parking required by Roanoke College.
See attached North Broad Street “Resubdivision Plat for Roanoke College - Zoning Exhibit” dated 6/7/2021
for additional details. The existing parcel is approximately 1.006 acres and is bounded by the public rights-
of-way of North Broad Street to the West and Red Lane to the East, and by RSF zoned property to the North
and South. The parcel generally drains from West to East towards Red Lane. The property has frontage on
two public roads, North Broad Street and Red Lane.
Buffers
An existing row of evergreen trees will provide an existing/natural buffer between the proposed RSF parcel
and the portion of the existing parcel to remain CUD.
Comprehensive Development Plan & Summary:
This project is in conformance with many of the Goals and Objectives defined in the City of Salem’s
Comprehensive Plan. This project is sensitive to the existing surrounding properties by maintaining existing
buffering, while utilizing a vacant property for an appropriate use to match surrounding land uses. This
project provides an excellent opportunity to the City of Salem to gain additional residential property in a
location of high demand, while supporting Roanoke College and helping to promote low density residential
development along North Broad Street.
Sincerely,
Benjamin T. Crew
Associate
PLANNERS / ARCHITECTS / ENGINEERS / SURVEYORS
ROANOKE / RICHMOND / NEW RIVER VALLEY / STAUNTON / HARRISONBURG / LYNCHBURG
DRAWN BY:BTC1208 Corporate Circle / Roanoke, Virginia 24018 / Phone (540) 772-9580 / www.balzer.cc
j:
\
2
1
\
0
0
\
0
4
\
0
4
2
1
0
0
3
6
.
0
0
n
o
r
t
h
b
r
o
a
d
s
t
r
e
e
t
-
r
o
a
n
o
k
e
c
o
l
l
e
g
e
\
c
i
v
i
l
\
d
w
g
\
0
4
2
1
0
0
3
6
.
0
0
z
o
n
i
n
g
b
a
s
e
_
.
d
w
g
LEGAL DESCRIPTION
PROPOSED PARCEL B
NORTH BROAD STREET
BEGINNING AT A POINT ON THE EAST LINE OF NORTH BROAD STREET,
SAID POINT LYING 132'± NORTH OF THE NORTH LINE OF DULANEY'S ALLEY;
THENCE ALONG THE EAST LINE OF NORTH BROAD STREET N 12°34'00" W THROUGH AN IRON
PIN FOUND AT 129.97', A TOTAL DISTANCE OF 137.26' TO A POINT IN THE CENTER OF VACATED
SHIPMAN ALLEY;
THENCE LEAVING THE EAST LINE OF NORTH BROAD STREET N 76°41'14" E A DISTANCE OF
111.91' TO A POINT;
THENCE WITH A NEW LINE S 13°18'46" E A DISTANCE OF 137.18' TO A POINT;
THENCE S 76°39'00" W A DISTANCE OF 113.69' TO A POINT ON THE EAST LINE OF NORTH
BROAD STREET;
WHICH IS THE POINT OF BEGINNING,
HAVING AN AREA OF 15,478 SQUARE FEET, 0.355 ACRES AND BEING IN THE CITY OF SALEM,
VIRGINIA.
AG - Agriculture District
BCD - Business Commerce District
CBD - C ommuni ty Business District
CUD - C ollege/U niversity District
DBD - D owntow n Business District
HBD - H ighway Business District
HBD/HM - Highw ay Business/Heavy Manufacturing District
HBD/LM - Highw ay Business/Li ght Manufacturing District
HM - Heavy Manufactur ing Distr ict
LM - Light Manufacturing District
LM/HM - Light M anufacturing/Heavy Manufacturing District
MHP - M anufactured Home Par k District
PUD - Planned Unit District
RB - Residential Business District
RMF - Residential Multi-Family District
RMF/RB - Residential Multi-Family/Residential Business District
RSF - Residential Single Family District
RSF/HBD - Residential Single/Highway Business District
RSF/LM - Residential Single Family/Light Manufacturing
RSF/RB - Residential Single Family/Residential Business District
RSF/RMF - Residential Single Family/Residential Multi-Family District
RSF/TBD - Residential Single Family/Transitional Business District
TBD - Transitional Business District
EXISTING ZONING FUTURE LAND USE
D u l a n e y s A l l e y
D u l a n e y s A l l e y
N
o
r
t
h
B
r
o
a
d
S
t
r
e
e
t
R
e
d
L
a
n
e
N
o
r
t
h
M
a
r
k
e
t
S
t
r
e
e
t
M c C l u n g S t r e e t
C o l l e g e A l l e y
T
r
u
s
t
e
e
s
o
f
R
o
a
n
o
k
e
C
o
l
l
e
g
e
,
P
B
1
0
,
P
G
1
9
R
o
a
n
o
k
e
C
o
l
l
e
g
e
,
P
B
1
1
,
P
G
1
9
1
2
3
4
1
2
3
4A
5A 5B
B
6
A
2
1
2
2
6B
1
1
5 0
4 0
3
0
5 5
1
6
2 0
3
0
1
6
1
6
1
4
1
6
Roanoke College
Roanoke College
Roanoke College
Roanoke College
City of Salem
Roanoke College
Roanoke College
City of Salem
1 4 ' S h i p m a n A l l e y V a c a t e d b y R e s o l u t i o n N o . 1 0 6 2 , d a t e d 9 /2 2 /0 5
Roanoke College
3
6
1
2
3
4
5
6
6.1
17
18
19
20
21
22
23
1
1.1
2
3
15
16
17
18
1
1
1
6.1
7
5
-
7
31.77
31.47
8
4
.
0
0
6
3
.6
8
1
2
7
.
0
0
2 3 5 .1 6
2 3 5 .1 6
2
4
2
.
4
0
1
3
6
.
0
5
2
0
3
.
4
0
2
0
3
.
4
0
3
4
8
.
0
0
1
1
4
.
5
7
2
8
7
.
1
8
2
8
7
.
1
8
3
4
8
.
0
0
1 7 7 .0 0
1 5 5 .8 8
1 4 6 .4 5
1
2
2
.
5
8
1
3
7
.
0
4
1 3 6 .3 8
2 3 7 .4 6
5
0
.
0
0
5
0
.
0
0
5
5
.
0
0
9
0
.
0
0
1
1
0
.
0
0
1
3
7
.
0
0
1
1
2
.
0
0
1
0
0
.
5
0
1
0
0
.
0
0
1
0
0
.
0
0
1
0
0
.
0
0
1
3
1
.
0
0
1
3
2
.
0
0
1
0
0
.
0
0
5
5
.
0
0
6
5
.
0
0
5
5
.
0
0
2 6 4 .0 0
1 2 5 .0 0
2 0 0 .0 0
2 6 4 .0 0
3 3 6 .0 0
1 6 2 .0 0
1 0 2 .0 0
1 8 0 .0 0
2 6 4 .0 0
2 6 4 .0 0
2 6 4 .0 0
29 2.0 0
2 6 5 .9 8
2 6 4 .0 0
2 6 5 .9 8
2 6 4 .0 0
1 4 2 .9 4
2 6 4 .0 0
1
0
0
.
0
0
1
0
0
.
0
0
1
3
1
.
0
0
1
3
2
.
0
0
5
5
.
0
0
6
5
.
0
0
8
6
.
0
0
7
0
.
0
0
8
5
.
0
0
1
1
9
.
0
0
5
0
.
0
0
5
5
.
0
0
5
0
.
0
0
9
0
.
0
0
1
1
0
.
0
0
2
3
8
.
2
0
2 0 0 .0 0
2 0 0 .0 0
2 0 0 .0 0
2 0 0 .0 0
2 0 0 .0 0
2 8 9 .1 0
6 5.0 0
7 0 .0 0
2 6 4 .0 0
1 2 5 .0 0
2 0 0 .0 0
3 0 9 .8 3
1 0 5 .0 0
1 7 9 .0 0
1 2 7 .0 0
1
3
3
.
0
5
1
0
3
.
4
0
1
0
0
.
0
0
2
0
3
.
4
0
2 4 2 .8 5
2 5 0 .0 0
2 6 5 .1 2
7
0
.
4
6
2 5 8 .0 0
2 5 3 .7 6
2
0
3
.
4
0
6
4
.
0
0
3 3 7 .9 7
2
7
3
4 1
2
5
3
3
0
3
1
9
-
3
0
5
2 0
3
2
4
3
2
0
3
1
6
3
1
2
3
0
6
2
2
0
2
1
2
2
0
2
3
1
3
2
2
3
2
3
3
1
1
7
,
1
1
9
,
1
2
1
3
3
5
2
0
3
-
2
0
5
-
2
0
7
-
2
0
9
-
2
1
1
2
1
3
2
0
1
3
2
7
3
1
9
3
0
7
3
0
1
2
3
2
2
3
5
-
2
2
1
-
2
1
9
2
2
6
2
4
7
1.547 Ac.
1.86 Ac.
1.19 Ac.
1.006 Ac.
0 100 20050
Feet±1 inch = 90 fee t AUGUST 2021 PLANNING COMMISSION ITEM 4B232 NORTH BROAD ST.
CITY OF SALEM
Community Development DepartmentP.O. Box 869Salem, Virginia 24153-0869Phone: (540) 375-3032
Tax Parcel 87-7-7 Buildings Parcels City Limits
Comme rcia l
Dow ntown
Econo mic De velopme nt A rea
In dus trial
In stitutio na l
Mixed Use
Public Pa rks and R ecre atio na l
Reside ntia l
Tran sitio nal
Ta x Parcel 87-7 -7 Bu ildings Pa rce ls City Limits
Item # 4C
Date: 8-11-2021
AT A REGULAR MEETING OF THE PLANNING COMMISSION OF THE CITY OF
SALEM, VIRGINIA held in Council Chambers of City Hall, 114 North Broad Street,
Salem, VA 24153
AGENDA ITEM: Major Subdivision
Consider the request for preliminary and final approval
of proposed subdivision plat and subdivision plan filed
by RFC2017 Land, LLC, property owner/developer, for a
7.767 acre tract known as the Village at North Mill,
Phase Four.
SUBMITTED BY: Benjamin W. Tripp, AICP, CEcD, City Planner
SUMMARY OF INFORMATION:
SITE CHARACTERISTICS:
Zoning: RSF Residential Single-Family District
Existing Use: Vacant
This plat would create 7 new lots in phase 4 of the Village at North Mill. These
lots are an extension of Woodside Drive, with a remnant lot to be included in a
future phase.
STAFF RECOMMENDATION:
This plat meets the City of Salem Subdivision Ordinance, and the Subdivision Plan
has been approved by staff. Staff recommends approval.
DRAWN BY:
1208 Corporate Circle / Roanoke, Virginia 24018 / Phone (540) 772-9580 / www.balzer.cc
PRE
L
I
M
I
N
A
R
Y
06/23/2021
j:
\
1
7
\
0
0
\
0
4
\
0
4
1
7
0
0
4
3
.
0
0
v
i
l
l
a
g
e
@
n
o
r
t
h
m
i
l
l
p
h
a
s
e
3
\
s
u
r
v
e
y
\
d
r
a
w
i
n
g
s
\
0
4
1
7
0
0
4
3
.
0
0
(
r
e
s
u
b
)
.
d
w
g
PLANNERS / ARCHITECTS / ENGINEERS / SURVEYORS
ROANOKE / RICHMOND / NEW RIVER VALLEY / STAUNTON / HARRISONBURG / LYNCHBURGEJP
CHECKED BY:DSH
SECTION 4
DRAWN BY:
1208 Corporate Circle / Roanoke, Virginia 24018 / Phone (540) 772-9580 / www.balzer.cc
PR
E
L
I
M
I
N
A
R
Y
06/23/2021
j:
\
1
7
\
0
0
\
0
4
\
0
4
1
7
0
0
4
3
.
0
0
v
i
l
l
a
g
e
@
n
o
r
t
h
m
i
l
l
p
h
a
s
e
3
\
s
u
r
v
e
y
\
d
r
a
w
i
n
g
s
\
0
4
1
7
0
0
4
3
.
0
0
(
r
e
s
u
b
)
.
d
w
g
PLANNERS / ARCHITECTS / ENGINEERS / SURVEYORS
ROANOKE / RICHMOND / NEW RIVER VALLEY / STAUNTON / HARRISONBURG / LYNCHBURGEJP
CHECKED BY:DSH
SECTION 4
PLANNERS / ARCHITECTS / ENGINEERS / SURVEYORS
ROANOKE / RICHMOND / NEW RIVER VALLEY / STAUNTON / HARRISONBURG / LYNCHBURGDRAWN BY:EJP
CHECKED BY:DSH 1208 Corporate Circle / Roanoke, Virginia 24018 / Phone (540) 772-9580 / www.balzer.cc
PR
E
L
I
M
I
N
A
R
Y
06/23/2021
j:
\
1
7
\
0
0
\
0
4
\
0
4
1
7
0
0
4
3
.
0
0
v
i
l
l
a
g
e
@
n
o
r
t
h
m
i
l
l
p
h
a
s
e
3
\
s
u
r
v
e
y
\
d
r
a
w
i
n
g
s
\
0
4
1
7
0
0
4
3
.
0
0
(
r
e
s
u
b
)
.
d
w
g
GENERAL NOTES
SEWER NOTES
SURVEY INFORMATION
SOIL EROSION NOTES
LEGEND
SHEET INDEXVICINITY MAP
WATER NOTES
REVISIONS
N
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
DE
M
O
L
I
T
I
O
N
P
L
A
N
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-2
N
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
OV
E
R
A
L
L
P
L
A
N
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-3
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
N
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
DI
M
E
N
S
I
O
N
A
L
P
L
A
N
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-4
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
N
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
DI
M
E
N
S
I
O
N
A
L
P
L
A
N
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-5
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
N
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
GR
A
D
I
N
G
P
L
A
N
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-6
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
N
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
GR
A
D
I
N
G
P
L
A
N
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-7
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
PR
O
F
I
L
E
S
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-8
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
*NOTE: ROAD AND UTILITY PROFILES SHOWN
ON THIS SHEET ARE APPLICABLE TO PREVIOUS
PHASES ARE NOT APPLICABLE TO PHASE 4.
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
PR
O
F
I
L
E
S
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-9
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
*NOTE: ROAD PROFILES SHOWN ON THIS
SHEET ARE APPLICABLE TO PREVIOUS
PHASES ARE NOT APPLICABLE TO PHASE 4.
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
PR
O
F
I
L
E
S
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-10
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
*NOTE: STORM PROFILES #5 AND #7 SHOWN ON
THIS SHEET ARE APPLICABLE TO PREVIOUS
PHASES ARE NOT APPLICABLE TO PHASE 4.
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
SW
M
D
E
T
A
I
L
S
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-11
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
N
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
ES
C
P
L
A
N
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-12
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
ES
C
N
O
T
E
S
&
D
E
T
A
I
L
S
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-13
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
NO
T
E
S
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-14
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
WE
S
T
E
R
N
V
A
R
E
G
I
O
N
A
L
D
E
T
A
I
L
S
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-15
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
12"-18"
WA
T
E
R
M
A
I
N
18" DIA.
VARIES
1" SERVICE
NOTE #4
1.SETTER TO BE A.Y. McDONALD 20-215WDDD33, FORD VBHH72-15W-11-33 OR APPROVED EQUAL.
2.SADDLES MUST BE USED WITH ALL PLASTIC & DUCTILE IRON PIPE. SERVICE SADDLES SHALL BE USED IN
ACCORDANCE WITH WATER DISTRIBUTION PIPING SPECIFICATION. SERVICE SADDLES FOR PLASTIC PIPE
SHALL BE: POWERSEAL 3417, OR 3412AS, ROMAC 202S, OR 306, OR FORD METER FS202 OR FS303. FOR
DUCTILE IRON PIPE USE THE ABOVE OR POWERSEAL 3413, ROMAC 202 OR FORD METER F202.
3.METER BOX SHALL BE CARSON/MID-STATES PLASTICS, INC. PLASTIC BOX WITH FORD A32-T
(ELECTRONIC READ LID) OR A. Y. McDONALD MODEL 74M32CTC CAST IRON BASE & COVER OR APPROVED
EQUAL. METER BOX SHALL NOT BE PLACED IN AREAS SUBJECT TO VEHICULAR TRAFFIC. IF TRAFFIC
BEARING BOX IS REQUIRED, DESIGN ENGINEER SHALL CONSULT WITH PARTICIPATING UTILITY TO
DETERMINE SITE SPECIFIC REQUIREMENTS.
4.CORPORATION STOP SHALL BE FORD F1000-4-G OR APPROVED EQUAL.
5.SERVICE SHALL BE "K" TYPE COPPER, OR COPPER TUBE SIZE POLYETHYLENE (PE) 4710, SODR-9 (200 psi).
6.WHENEVER SIDEWALK EXISTS OR IS PROPOSED, MODIFY METER LOCATION AS DIRECTED.
FINAL GRADE
6" MIN
32"
46"
(TYP.)
12" MAX. VERTICAL
ADJUSTMENT
1. FIRE HYDRANTS MAY BE USED AT LOW POINTS IN PLACE OF BLOW-OFFS.
2. LINE AND "STREET ELS" BETWEEN CORPORATION STOP AND 2" GATE VALVE SHALL BE LEAD FREE BRASS.
3. THE POINT OF CONNECTION TO THE WATER MAIN SHALL BE LOCATED NEAR THE BOTTOM OF THE MAIN (AS
SHOWN) TO FACILITATE REMOVAL OF ACCUMULATED SEDIMENT.
4. SADDLES FOR PLASTIC PIPE SHALL BE PER RESIDENTIAL WATER SERVICE DETAIL.
VARIES
3'
M
I
N
.
C
O
V
E
R
CONTINUOUS
SECTION OF PIPE SECTION OF PIPE
CONTINUOUS
2'X2'X4"CONCRETE PAD
1.PUBLIC HYDRANTS SHALL BE PAINTED SILVER WITH AN OIL-BASED PAINT AND PRIVATE HYDRANTS SHALL
BE PAINTED WHITE WITH AN OIL-BASED PAINT.
2.FIRE HYDRANT SHALL BE INSTALLED 2' MIN. AND 4' MAX. FROM BACK OF CURB OR 6' MIN. AND 12' MAX.
FROM EDGE OF PAVEMENT WHEN CURB IS NOT PRESENT. FIRE HYDRANT TO BE INSTALLED WITHIN
RIGHT-OF-WAY OR EASEMENT LINE.
3.AREA AROUND HYDRANT AT A RADIUS OF 4' TO BE LEVEL AND UNOBSTRUCTED.
4.WATERPROOF BAGS OR OUT OF SERVICE RINGS SHALL BE PLACED OVER ALL NEWLY INSTALLED FIRE
HYDRANTS.
5.HIGH PRESSURE (OVER 120 PSI) REQUIRES THE USE OF ALL 3 RESTRAINTS.
6.IF DURING CONSTRUCTION THE SEASONAL WATER LEVEL IS NOTED TO BE ABOVE THE DRAIN OUTLETS OF
THE PROPOSED HYDRANT. THE PARTICIPATING UTILITY WILL BE NOTIFIED IMMEDIATELY SO THAT THE
HYDRANT CAN BE RELOCATED TO A SUITABLE LOCATION, OMITTED, OR THE DRAIN HOLE PLUGGED.
7.TWO WRAPS OF TRACER WIRE SHALL BE WRAPPED AROUND BASE OF HYDRANT.
8.APPROVED MODELS - AVK MODEL 2780, AFC MODEL B-84-B-5, MUELLER CENTURION A423, KENNEDY K81D
EQUIVALENT.
AVK MODEL 2780,
AFC MODEL B-84-B,
MUELLER CENTURION
A423, KENNEDY K81D
EQUIVALENT.
1'
-
6
"
T
O
2
'
-
0
"
AB
O
V
E
C
U
R
B
OR
E
D
G
E
O
F
PA
V
E
M
E
N
T
18"
MIN.
C SQ.
D SQ.
45°
B
B
A
A
X
X
6" MIN.6" MIN.
A A
X
X
PIPE
SIZE
4"
6"
8"
10"
12"
16"
24"
30"
90° BEND
A
8"
18"
18"
20"
20"
26"
82"
185"
B
12"
12"
13"
16"
16"
20"
42"
42"
45° BEND
A
8"
8"
10"
12"
12"
16"
62"
100"
B
8"
10"
10"
14"
14"
18"
30"
42"
22 1/2° BEND
A
6"
8"
8"
8"
8"
11"
44"
52"
B
6"
8"
8"
12"
12"
13"
22"
42"
11 1/4° BEND
A
6"
8"
8"
8"
8"
11"
22"
40"
B
6"
8"
8"
12"
12"
13"
16"
30"
TEE
A
11"
11"
11"
14"
18"
82"
185"
B
9"
10"
12"
16"
16"
20"
42"
42"
14"
PLUG
C
10"
12"
12"
16"
16"
20"
82"
185"
D
6"
18"
24"
30"
30"
36"
42"
42"
10" MIN.
TYP. CONC. THRUST
COLLAR MIN. 2"
INTO UNDISTURBED
MAT. ON 3 SIDES
NOTES:
1. FOR VERT. BEND DOWN IN EXCESS OF
11 1
4" BEND, ANCHORAGE SHALL BE
DESIGNED BY ENGINEER.
2. FOR VERT. BEND UPWARD, BLOCKING TO
BE SIMILAR TO THAT FOR HORIZ. BEND.
3. GLANDS & BOLTS SHALL BE PROTECTED
FROM CONC. WITH PLASTIC SHEETING
WHEN POURING THRUST BLOCKS.
4. ALL THRUST BLOCK & SUPPORT CONC.
SHALL BE 3000 PSI READY MIX CONC.
5. THRUST BLOCKS WITH "B" DIMENSION
GREATER THAN 30" SHALL HAVE THE
RESTRAINED PIPE INSTALLED WITH A
MINIMUM OF 4' OF COVER.
6. IF UNDER 100 PSI WORKING PRESSURE,
RESTRAINED JOINTS MUST BE USED.
IF EQUAL OR GREATER THAN 100 PSI BOTH
BLOCK AND RESTRAINED JOINTS ARE REQUIRED.
TRENCH
BOTTOM
TYP. M.J. BEND W/
RESTRAINER GLANDS
18" MIN.-10"DIA. & LESS
24" MIN.-12"DIA. & GREATER 16 #4 BARS EACH
WAY AS SHOWN
THRUST
BLOCK (TYP.)
UNDISTURBED
SOIL (TYP.)
PRESSURE= 200psi
BEARING= 2000psf
FACTOR OF SAFETY= 1.5
1.5
17'
27'
22'
18'
15'
11'
56'
46'
35'
37'
30'
23'
30'
31'
29'
20'
21'
20'
82'
56'
38'
57'
47'
34'
89'
74'
56'
61'
51'
38'
9'
8'
6'
9'
7'
6'
20'
16'
12'
19'
15'
12'
47'
40'
30'
45'
37'
28'
PVC
PVC
PVC
D.I.
D.I.
D.I.
10"
8"
6"
6"
8"
10"
12"PVC 56'23'11'106'88'56'66'32'
12"D.I.53'22'11'73'69'38'43'21'10'
16'
5'
7'
9'
11'
13'
8'
5'
6'
3'
4'
4'
3'
4'
5'
1. ALL JOINTS SHALL BE RESTRAINED ON BOTH SIDES OF THE FITTING FOR THE
LENGTH SHOWN UNLESS OTHERWISE INDICATED.
2. REDUCER IS ONE SIZE SMALLER THAN PIPE LISTED. RESTRAINED LENGTH IS
UPSTREAM ON THE LARGE SIDE OF THE REDUCER.
3. IF UNDER 100 PSI WORKING PRESSURE, RESTRAINED JOINT(S) ARE TO BE USED.
IF EQUAL TO OR OVER 100 PSI WORKING PRESSURE, BOTH THRUST BLOCK
AND RESTRAINED JOINTS SHALL BE USED.
1.TAPPING SLEEVE SHALL BE POWERSEAL MODEL 3490 TYPE 304 STAINLESS STEEL WITH CARBON STEEL FLANGE, ROMAC'S MODEL
SST III, FORD MODEL FTSS WITH CARBON STEEL FLANGE OR APPROVED EQUIVALENT. SLEEVE SHALL BE RATED AT 100 PSI OVER
WORKING PRESSURE AND MUST HAVE A TEST PLUG.
2.TAPPING VALVE SHALL BE AVK RESILIENT SEATED GATE VALVE SERIES 25 MJFL OR MUELLER T-2360 RESILIENT WEDGE TAPPING
VALVE WITH MJFL. VALVE SHALL BE RATED AT 250 PSI.
3.TAPPING SLEEVE AND VALVE SHALL BE FULL PORT TO ACCEPT FULL SIZE SHELL CUTTER.
4.STEEL FLANGE SHALL MEET AWWA C207.
5.SIZE-ON-SIZE TAPPING NOT ALLOWED UNLESS APPROVED BY PARTICIPATING UTILITY.
1" CORPORATION STOP
WITH CTS COMPRESSION
CONNECTION SEE NOTE #5
3/4" Ø x 6' PIG TAIL
TO BE CAPPED &
MARKED OR STAKED
METER SETTER & BOX TO BE
SET AT FINAL GRADE OF SITE
DUAL CHECK VALVE
LOCKABLE SHUTOFF
TRACER WIRE
SEE GENERAL DETAIL
CAPITOL FOUNDRY MH 2001
NON-WATERTIGHT FRAME & COVER
LABELED "WATER"
PAVEMENT
ADJUSTMENT RING
GROUND BAR
SEE GENERAL
DETAIL
PROPOSED
VALVE
6" COMPACTED
VDOT 57
WATER
MAIN
TRACER & GROUND WIRES
SEE GENERAL DETAIL
PRECAST WATER VALVE VAULT
OR PRECAST MANHOLE SECTION(S)
IF DEPTH EXCEEDS 5'
2" CLEARANCE FROM
TOP OF PIPE TO BOTTOM
OF VAULT CUT-OUT
PAVEMENT
ADJUSTMENT RING
(WHEN REQUIRED)
GROUND BAR
SEE GENERAL DETAIL
PRECAST WATER VALVE
VAULT OR PRECAST
MANHOLE SECTION(S)
WHEN DEPTH EXCEEDS 5'
2" GATE VALVE
WITH 2" SQUARE
HEAD
6" MINIMUM
VDOT 57
FINISHED GRADE
TRACER & GROUND
WIRES SEE GENERAL
DETAIL
2" TAPPING SADDLE
2" CORPORATION
STOP MUELLER
H-15000 OR
EQUIVALENT
2" THREADED
NIPPLE WITH
FINGER TIGHT CAP
DRILL 1/4" Ø
HOLE IN CAP
6" MIN.
12" MAX. VERTICAL
RIGHT-OF-WAY
EASEMENT LINE
PRIVATE
PROPERTY
2 - 2 1/2"
NOZZLES
FINISHED GRADE
1 - 4 1/2" PUMPER
NOZZLE (FACING THE ROAD)
VALVE BOX OUTSIDE
PAVEMENT OR VALVE
VAULT UNDER PAVEMENT
STANDARD INSTALLATION
INCLUDES FOSTER ADAPTER
OR APPROVED EQUAL
WATER
MAIN
CONCRETE
THRUST BLOCK
TEE - MAIN
LINE SIZE
BY 6"
M.J. FITTINGS SHALL NOT
BE ENCASED IN CONCRETE
APPROVED M.J. GLAND RESTRAINT
(i.e. MEGALUGS, GRIP RINGS OR
UNI-FLANGE) MAY BE SUBSTITUTED
FOR CONCRETE THRUST BLOCKS
TRACER WIRE SEE GENERAL DETAIL
3/4" DIA. "CORTEN"
THREADED ROD AND NUTS
CONCRETE BASE AND THRUST
BLOCK AGAINST UNDISTURBED
SOIL, CONCRETE SHALL NOT
COVER HYDRANT DRAIN
0.5 CY CLEAN
STONE VDOT #57
FOR DRAINAGE
CAPITOL FOUNDRY MH 2001
NON-WATERTIGHT FRAME & COVER
LABELED "WATER"
SADDLE & STOP
12" MIN.
1. SEE RESIDENTIAL WATER SERVICE DETAIL FOR SADDLE REQUIREMENTS.
2. LARGER COMBINATION VALVE MAY BE REQUIRED DEPENDING ON APPLICATION.
PAVEMENT FINISHED GRADE
6" MIN.
TRACER & GROUND
WIRES SEE GENERAL
DETAIL
GROUND BAR
SEE GENERAL DETAIL
PRECAST WATER VALVE
VAULT OR PRECAST
MANHOLE SECTION(S)
WHEN DEPTH EXCEEDS 5'
ADJUSTMENT RING
(WHEN REQUIRED)
COMBINATION
AIR VALVE
APCO 143C,
A.R.I. D-040, OR
EQUIVALENT
1" CORPORATION
STOP MUELLER
H-15000 OR
EQUIVALENT
6" MINIMUM
VDOT 57
SEE NOTE #1
12" MAX. VERTICAL
PROVIDE
SS METAL
SCREEN
CAPITOL FOUNDRY MH-2001
NON-WATER TIGHT FRAME AND
COVER LABELED "WATER"
COPPER
PIPING
COMPACTED VDOT 57
TO BOTTOM OF VAULT
AS SHOWN ABOVE
SEE NOTE #1
1" CORPORATION
STOP MUELLER
H-15000 OR
EQUIVALENT
1" GATE VALVE
1" THREADED LEAD FREE BRASS PIPE
LENGTH AS REQUIRED TO COMPLETE
FULL ASSEMBLY AS SHOWN ABOVE
WATER
MAIN
WATER
MAIN
WATER
MAIN
01/01/12
WIRES
TRACER
1.TRACER WIRES SHALL BE INSTALLED USING MANHOLES, VALVE BOXES OR VAULTS, WATER
METERS AND FIRE HYDRANTS AS ACCESS POINTS.
2.FOR WATER OR SEWER INSTALLED BY OPEN TRENCHING, TRACER WIRE SHALL BE COPPERHEAD
INDUSTRIES COPPER CLAD STEEL DIRECT BURY #14 AWG SOLID (.0641" DIAMETER), STEEL CORE
SOFT DRAWN HIGH STRENGTH TRACER WIRE, 250# AVERAGE TENSILE BREAK LOAD, 30 MIL HIGH
MOLECULAR WEIGHT-HIGH DENSITY (GREEN OR BLUE) POLYETHYLENE JACKET COMPLYING WITH
ASTM-D-1248, 30 VOLT RATING. A HEAVIER GAUGE MAY BE REQUIRED FOR DEPTHS EXCEEDING
SIX FEET.
3.FOR WATER OR SEWER INSTALLED BY HORIZONTAL DIRECTIONAL DRILLING METHOD, TRACER
WIRE SHALL BE COPPERHEAD INDUSTRIES COPPER CLAD STEEL DIRECT BURY #12 AWG SOLID
(.0808" DIAMETER), STEEL CORE HARD DRAWN EXTRA HIGH STRENGTH HORIZONTAL DIRECTIONAL
DRILL TRACER WIRE, 1150# AVERAGE TENSILE BREAK LOAD, 45 MIL HIGH MOLECULAR
WEIGHT-HIGH DENSITY (GREEN OR BLUE) POLYETHYLENE JACKET COMPLYING WITH ASTM-D-1248,
30 VOLT RATING.
4.SPLICES SHALL BE MADE USING COPPERHEAD INDUSTRIES SNAKE BITE SPLICE KIT PART #SCX-01,
OF THE APPROPRIATE COLOR, 3M DIRECT BURY SPLICE KIT (DBY), OR EQUIVALENT.
5.TRACER WIRE SHALL BE LONG ENOUGH TO EXTEND A DISTANCE OF FIVE (5) FEET BEYOND THE
STRUCTURE.
6.AS-BUILTS SHALL SHOW TRACER WIRE(S) LOCATION AND ACCESS POINT(S).
7.THE TRACER WIRE SHALL BE PLACED ALONG THE LOWER QUADRANT OF THE PIPE. THE WIRE
SHALL NOT TOUCH THE PIPE, BUT SHALL BE A MAXIMUM OF 6" FROM THE PIPE. NON-METALLIC
SPACERS MAY BE USED TO MAINTAIN A SET DISTANCE FROM THE UTILITY.
8.WHERE LINES ARE GREATER THAN SIX (6) FEET IN DEPTH, WIRE SHALL BE BROUGHT TO THE
SURFACE EVERY ONE-HUNDRED (100) FEET AND PLACED IN A WATER METER BOX OR APPROVED
JUNCTION BOX.
9.THE TRACER WILL BE TESTED BY THE PARTICIPATING UTILITY AS PART OF THE PROJECT'S FINAL
ACCEPTANCE.
10.THE GROUND WIRE SHALL BE #6 GAUGE COPPER WIRE AND SHALL BE OF ADEQUATE LENGTH TO
EXTEND A MINIMUM OF FIVE (5) FEET BEYOND THE TOP OF STRUCTURE. THE END OF GROUND
WIRE SHALL CONNECT TO THE GROUND BAR USING A BURNDY KA6U MECHANICAL CABLE LUG.
11.A GROUND ROD SHALL BE INSTALLED AT EACH LOCATION WHERE GROUND WIRE SURFACES AND
CONNECTS TO GROUND BAR. GROUND ROD SHALL BE COPPER COATED, MINIMUM DIAMETER OF
5/8", AND SHALL BE BURIED A MINIMUM OF FOUR (4) FEET INTO THE GROUND.
12.THE GROUND BAR SHALL BE STAINLESS STEEL AND SHALL BE ATTACHED USING SS 1/4" X 1 1/4" SS
HEX TAPCON. THE FOLLOWING SHALL BE INSTALLED IN 4 (FOUR) CENTER HOLES: 10-32 SS NUTS,
#10 SS WASHERS AND 10-32 X 3/4 SS PHILLIPS. THE FOURTH HOLE SHALL HAVE A BURNDY
CONNECTOR KA6U FOR THE #6 GAUGE GROUND WIRE. THE ASSEMBLY CAN BE ACQUIRED AT
MAGIC CITY SUPPLY - CLAMP RFC-11. THE ENDS OF THE TRACER WIRES SHALL BE PLACED IN THE
GROUND BAR AS SHOWN.
13.TWO WRAPS OF TRACER WIRE SHALL BE WRAPPED SNUGGLY AROUND BASE OF HYDRANT. WIRE
SHALL NOT BE LEFT IN A WAY THAT WOULD INTERFERE WITH MOWING AROUND HYDRANT.
12"-18"
12" MIN.
6" STONE
VDOT 57
01/01/12 01/01/12 01/01/12 01/01/12
01/01/12 01/01/12 01/01/12 01/01/12
METER
BY PARTICIPATING
UTILITY
(NO OBSTRUCTIONS)
CONTRACTOR TO EXPOSE
& CLEAN PIPE IN
ACCORDANCE WITH
MANUFACTURERS
RECOMMENDATIONS
GROUND WIRE
TO GROUNDING
SOURCE
GROUND ROD
SEE GENERAL DETAIL
GROUND ROD
SEE GENERAL DETAIL
GROUND ROD
SEE GENERAL DETAIL
FILTER FABRIC
1. FILTER FABRIC TO BE INSTALLED BETWEEN BOTTOM OF PIPE AND STONE BEDDING. FABRIC TO EXTEND
VERTICALLY A MINIMUM OF 6" FROM BOTTOM OF VAULT (FULL CIRCUMFERENCE).
***SERVICE LINE SHALL BE COPPER
***METER BOX LID SHALL BE RECTANGULAR
NICOR READ-RITE LIB MODEL
B9XNLBLKWATFL WITH "WATER" LOGO
TH
E
V
I
L
L
A
G
E
A
T
N
O
R
T
H
M
I
L
L
WE
S
T
E
R
N
V
A
R
E
G
I
O
N
A
L
D
E
T
A
I
L
S
CI
T
Y
O
F
S
A
L
E
M
,
V
I
R
G
I
N
I
A
C-16
www.balzer.cc
RESIDENTIAL LAND DEVELOPMENT ENGINEERING
SITE DEVELOPMENT ENGINEERING
LAND USE PLANNING & ZONING
LANDSCAPE ARCHITECTURE
LAND SURVEYING
ARCHITECTURE
STRUCTURAL ENGINEERING
TRANSPORTATION ENGINEERING
ENVIRONMENTAL & SOIL SCIENCE
WETLAND DELINEATIONS & STREAM EVALUATIONS
Roanoke
New River Valley
Richmond
Staunton
Harrisonburg
Balzer and Associates, Inc.
1208 Corporate Circle
Roanoke, VA 24018
540-772-9580
FAX 540-772-8050
4'-0"
GROUT
ANNULAR SPACE
(TYP. INLET & OUTLET)
A
BUTYL MASTIC JOINT SEALER OR GASKETS
MEETING ASTM C443 AND ASTM C1244 TESTING
STANDARD (NO MORTAR)
ADJUSTMENT RINGS IF NECESSARY
(1'-0" MAX ADJUSTMENT)
SEE FRAME & COVER DETAILS
A
ECCENTRIC CONE
HEIGHT VARIES
MANHOLE WITH
PRECAST INVERT
SERVICE
CONNECTION
BASE
HEIGHT VARIES
2'-0"
1.STRADDLE MANHOLE NOT ACCEPTABLE UNLESS APPROVED BY PARTICIPATING UTILITY.
2.MATERIALS AND FABRICATION IN ACCORDANCE WITH ASTM C478-09, AND ASTM C1619.
3.SEE DETAIL S-1 FOR ADDITIONAL MANHOLE REQUIREMENTS.
4.WATERSTOP TO BE GREENSTREAK HYDROTITE OR LEAKMASTER LV-1. WATERSTOP MUST BE ALLOWED
TO FULLY CURE BEFORE CONTACT WITH WET CONCRETE IS ALLOWED.
5.FIRST POUR: TOP SURFACE OF FIRST POUR SHALL CREATE A SMOOTH, FLAT, LEVEL BEARING SURFACE
TO FACILITATE A WATERTIGHT SEAL BETWEEN POURED BASE AND PRECAST MANHOLE SECTION.
CONCRETE SHALL BE 3,000 PSI CONCRETE AND MUST CURE 7-DAYS BEFORE SETTING MANHOLE
SECTION.
6.SECOND POUR: MANHOLE SHALL BE COMPLETELY SET INCLUDING FRAME AND COVER BEFORE PLACING
SECOND POUR. CONCRETE BONDING AGENT SHALL BE APPLIED TO ALL SURFACES/COLD JOINTS WHERE
NEW CONCRETE IS TO BE POURED AGAINST EXISTING. CONCRETE SHALL BE 3,000 PSI AND SHALL BE
ALLOWED TO CURE FOR 3-DAYS PRIOR TO PLACING BACKFILL.
MACHINED SURFACE
SECURE NUT
3/4" STAINLESS STEEL THREADED ROD
AND NUTS (4 TYP.) 3 1/8" 1/2"
Ø 26"
13/16" 1 1/2"
1/2"
1 3/8"
3 13/16"
9/16"
1 5/8"
I R G I N I AV W E S T E R N 1"
1.MATERIALS AND FABRICATION IN ACCORDANCE WITH ASTM C478-09.
2.WHEN USED AS SAMPLING MANHOLE FLOW SHALL PASS STRAIGHT THROUGH, i.e., 180°.
3.STEPS SHALL BE VERTICALLY ALIGNED. FIRST STEP SHALL BE WITHIN 12" OF COVER, BOTTOM STEP
SHALL BE WITHIN 24" OF BOTTOM OF MANHOLE.
4.FRAME AND COVER SHALL BE PROPERLY ALIGNED WITH THE 2 FOOT OPENING OF THE MANHOLE
STRUCTURE AND BOLTED IN PLACE.
5.FLAT TOP MANHOLES MAY ONLY BE SUBSTITUTED WITH THE PERMISSION OF THE PARTICIPATING UTILITY.
6.FLEXIBLE JOINT MANHOLE CONNECTION SHALL BE AS MANUFACTURED BY PRES-SEAL GASKET
CORPORATION OR EQUAL.
7.GROUT ANNULAR SPACE BETWEEN PIPE AND PRECAST MANHOLE ON INSIDE OF MANHOLE.
8.WHEN REPLACING AN EXISTING MANHOLE OR INSTALLING A NEW PRECAST MANHOLE ON AN EXISTING
SEWER, A MINIMUM OF SIX FEET (6') OF EXISTING PIPE SHALL BE REMOVED AND REPLACED WITH NEW
MATERIAL ON INLET AND OUTLET OF MANHOLE.
9.MANHOLES WHERE THE INVERT IS LOWER THAN THE NORMAL GROUNDWATER ELEVATION (I.E., ALONG
CREEKS, RIVERS, LOW-LYING AREAS, ETC.) SHALL HAVE A FULL EXTERIOR COATING AND JOINT WRAP
APPLIED IN ADDITION TO JOINT SEALANT. SEE NOTES 10 & 11.
10.IF REQUIRED EXTERIOR VERTICAL WALL SURFACES SHALL BE FACTORY COATED IN ACCORDANCE WITH
THE MANUFACTURERS RECOMMENDATION. COATING SHALL BE HIGH BUILD COAL TAR EPOXY MEETING
ASTM D1227. COATING SHALL BE APPLIED IN TWO COATS TO A MINIMUM TOTAL THICKNESS OF 16 MILS.
11.IF REQUIRED ALL MANHOLES SHALL UTILIZE AN EXTERNAL FRAME AND
JOINT SEAL AT ALL JOINTS AND AT THE FRAME/CHIMNEY
INTERFACE. SEAL SHALL BE MADE OF EPDM RUBBER IN
ACCORDANCE WITH ASTM D412 OR POLYOLEFIN BACKED
EXTERIOR JOINT WRAP IN ACCORDANCE WITH ASTM E-1745,
C-877, AND C-990. EDM SEAL SHALL HAVE A MINIMUM
THICKNESS OF 60 MILS. POLYOLEFIN BACKED EXTERIOR
JOINT WRAP SHALL HAVE A BACKING BAND ELEMENT WITH
MINIMUM THICKNESS OF 4 MILS. AND BUTYL ROLLER
ADHESIVE WITH MINIMUM THICKNESS OF 60 MILS.
SEAL SHALL AGGRESSIVELY BOND TO CONCRETE
AND METAL STRUCTURES.
12.FOR PIPE LARGER THAN 15 INCHES IN DIAMETER
THE MINIMUM INSIDE DIAMETER OF THE MANHOLE
SHALL BE IN ACCORDANCE WITH MANUFACTURERS
RECOMMENDATIONS BASED ON PIPE SIZE AND
ANGLE BETWEEN INLET AND OUTLET PIPING.
1.WATERTIGHT MANHOLE FRAME MODEL #1045Z BY EAST JORDAN IRON WORKS, INC. OR EQUIVALENT.
2.HDPE ADJUSTMENT RINGS SHALL MEET H-20 LOAD RATING, AND SHALL BE INTERLOCKING OR UTILIZE
BUTYL MASTIC JOINT SEALANT BETWEEN EACH RING TO FORM A WATERTIGHT JOINT.
3.CONCRETE ADJUSTMENT RINGS SHALL MEET H-20 LOAD RATING AND UTILIZE BUTYL MASTIC JOINT
SEALANT BETWEEN EACH RING AND FRAME AN COVER TO FORM A WATERTIGHT JOINT.
4.FRAME HEIGHT SHALL BE 7" FOR BURIED LOCATIONS AND 4" FOR EXPOSED LOCATIONS.
01/01/12 01/01/12 01/01/12 01/01/12
1'-4" Max.
3/4" Ø SS THREADED ROD
(IF ADJUSTMENT RINGS
ARE REQUIRED)
1 1/2"
PRECAST HOLE (TYP.)
FLEXIBLE BOOT WITH
STAINLESS STEEL
BAND (TYP.)
1/4" DIA.
NEOPRENE GASKET
STOP LUGS
FOR CAM
2" LETTERS
(RECESSED
FLUSH)NON-SLIP
TEXTURE
(2) CLOSED
PICKHOLES
(2) PICKBARS
SEE DETAIL
BELOW
2" LETTERS
(RECESSED
FLUSH)
Ø 25"
O.D. OF GKT GROOVE
1/4" Ø
NEOPRENE
GASKET
.63" Ø STAINLESS
STEEL ROD
Ø 22 13/16"
SECTION VIEW
PICKBAR DETAIL
BOTTOM VIEW
OF COVER
SECTION A-A
12"' MIN.
(TYP.)
A
CONTINUOUS WATERSTOP
APPLIED AROUND PIPE &
MANHOLE OPENING (TYP.);
ALLOW TO CURE BEFORE
PLACING CONCRETE
(SEE NOTES)
CONCRETE BASE
EXISTING PIPE
CUT OUT TOP OF PIPE TO SPRINGLINE;
MAXIMUM LENGTH = MANHOLE Ø - 2'-0";
SLOPE CONCRETE TO CUT-OUT
CONTINUOUS BUTYL MASTIC
JOINT SEALER, ASTM C1619
(BOTH SIDES)
PLAN VIEW
4" MIN. CLEARANCE
AROUND PIPE
SECOND POUR
(SEE NOTES)
SMOOTH, FLAT, LEVEL
BEARING SURFACE
FIRST POUR
(SEE NOTES)
SECTION A-A
#4 BARS @ 6" O.C.,
EACH WAY; TIED;
USE 3" REBAR SUPPORTS
WATERSTOP (SEE NOTES)
CONTINUOUS BUTYL MASTIC
JOINT SEALER
COLD JOINT (SEE NOTES)
SEE DETAIL S-1
FOR CONTINUATION 12"' MIN.
A
M
H
D
I
A
.
STONE BASE (6" MIN. DEPTH)
#57 OR EQUIVALENT
STONE BASE (6" MIN. DEPTH)
#57 OR EQUIVALENT
SLOPE BENCH
1/4" PER 1'-0"
PRECAST HOLE
WITH FLEXIBLE
BOOT & STAINLESS
STEEL BAND
MINIMUM SLOPE FOR
SERVICE CONNECTION
4" Ø=1/4" PER 1'-0"
6" Ø=1/8" PER 1'-0"
PRECAST MANHOLE
PRECAST MANHOLE
1.TRAFFIC BEARING BOX AND LID REQUIRED IN TRAFFIC AREAS (CAPITOL FOUNDRY VB-9*S).
2.ALL PIPE AND FITTINGS SHALL BE OF SIMILAR MATERIAL.
3.ALL PIPE SHALL BE OF SAME SIZE.
4.NO BENDS ARE ALLOWED IN THE LATERAL FROM THE MAIN TO THE CLEANOUT STACK TEE. (EXCEPT FOR
DEEP SEWER, AS SHOWN BELOW)
5.ALL MAIN LINE TAPS ON ACTIVE MAINS SHALL BE PERFORMED BY PARTICIPATING UTILITY.
6.PIPING ON PRIVATE SIDE OF CLEANOUT TO BE INSTALLED PER GOVERNING JURISDICTION REQUIREMENTS.
7.MINIMUM LATERAL SIZE: 4" FOR RESIDENTIAL SERVICE, 6" FOR NON-RESIDENTIAL SERVICE
8.MINIMUM COVER FOR ALL SEWER LATERALS SHALL BE THREE (3') FEET.
9.PROPERTY OWNER RESPONSIBLE FOR INSTALLING CLEANOUT ON PROPERTY LINE (IN ACCORDANCE WITH
THIS DETAIL) WHEN MAINTENANCE OCCURS.
10.LOWEST SERVED FINISHED FLOOR ELEVATION SHALL BE A MINIMUM OF THREE FEET (3') ABOVE THE TOP OF
THE MAIN AT THE POINT WHERE THE SERVICE LATERAL CONNECTS TO THE MAIN.
11.WHEN CONNECTING TO EXISTING LATERAL USE FERNCO FLEXIBLE COUPLING.
RIGHT OF WAY OR LIMITS OF EASEMENTPRIVATE PROPERTY
FINISHED GRADE
CLEAN OUT BOX AND LID
(SET TO FINISHED GRADE)
45° WYE
TEE NOT ACCEPTABLE
1/4" PER 1'- 0"
MINIMUM GRADE
SOLID GLUE CAP
ROUGH
GRADE
CLEAN-OUT STACK
SDR 35 (MINIMUM 4" Ø)
MAX.45o
11.25° OR 22.5°
BEND
SEWER
MAIN
SAME AS
ABOVE
01/01/12
SDR 35
TEE, WYE, TEE/WYE OR
COMBINATION OF WYE & 45°
BEND FITTINGS SHALL BE
SIZED AS REQUIRED
45°MAX.
45° OR 22.5° BELL
& SPIGOT BEND
(IF NEEDED)
CLEAN-OUT TO EXTEND ABOVE GROUND
A MIN. OF 3 FEET DURING INSTALLATION
OF MAIN LINE. PLUMBER SHALL CUT
STACK TO FINISHED GRADE AS SHOWN
WHEN BUILDING SEWER IS CONNECTED
TO LATERAL
PLASTIC BODY
CLEAN-OUT & CAP
4" MINIMUM
GRAVEL BEDDING
#57 OR EQUIVALENT
SCHEDULE
40/SDR 35
HORIZONTAL SECTION SHALL
EXTEND A MINIMUM OF 5' OR
AS DIRECTED BY THE
PARTICIPATING UTILITY
SDR 35
(TYP.)
3' MIN.
12"12"PIPE DIA.
LIMITS
EXCAVATION
1.BEDDING, HAUNCHING AND INITIAL BACKFILL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THIS
DETAIL AND MANUFACTURER'S RECOMMENDATION.
2.ALL PVC PIPE SHALL BE BEDDED IN COMPACTED VDOT #57 OR #58 STONE, OR CRUSHER RUN.
3.IN AREAS SUBJECTED TO VEHICULAR TRAFFIC, BEDDING STONE AND FILL SHALL BE PLACED IN 6"
LIFTS FROM BOTTOM OF TRENCH TO 1' ABOVE THE PIPE AND THE REMAINING SHALL BE PLACED IN
10" LIFTS AND SHALL BE COMPACTED TO AT LEAST 90% OF MAXIMUM DENSITY AS DETERMINED BY
ASTM D 698.
4.BEDDING REQUIREMENTS FOR DUCTILE IRON WATER LINE ARE DEPENDENT ON MANUFACTURER'S
BEDDING CRITERIA.
5.ALL EXCAVATIONS SHALL COMPLY WITH OSHA TECHNICAL MANUAL, CHAPTER 2, TITLED
"EXCAVATIONS: HAZARD RECOGNITION IN TRENCHING AND SHORING."
6.THE TRACER WIRE SHALL BE PLACED ALONG THE LOWER QUADRANT OF THE PIPE. THE WIRE SHALL
NOT TOUCH THE PIPE, BUT SHALL BE A MAXIMUM OF 6" FROM THE PIPE. NON-METALLIC SPACERS
MAY BE USED TO MAINTAIN A SET DISTANCE FROM THE UTILITY.
(4" MIN. - 6" IN
ROCK CONDITIONS)
MINIMUM REQUIRED
TRENCH WIDTH
FOR SEWER LINES BEDDING
SHALL BE 6" ABOVE PIPE
AGGREGATE BACKFILL TYPE 1
#21B COMPACTED TO 95%
MAX. DENSITY IN 6" LIFTS
PIPELINE
SIZE & MATERIAL
AS SHOWN ON PLAN
TACK COAT
0.05-0.15 GAL.
SHALL CONFORM
TO REQUIREMENTS
OF ASHTO M208
PER SY (TYP.)
10" ASPHALT CONCRETE
COURSE TYPE BM-25.0
BENCH 12"
MIN. (TYP.)
BEDDING 4" MIN.
6" MIN. IN ROCK CONDITIONS
****
MILL 1 1/2" FULL DEPTH
DO NOT TAPER (TYP.)
EXISTING
PAVEMENT
SURFACE
8" AGGREGATE BASE MATERIAL
TYPE 1 #21B SUB-BASE COURSE
ASPHALT CONCRETE
SURFACE COURSE
TYPE SM-9.5A
165 LBS./SY
CL
FINISHED GRADE
PIPE SIZE & MATERIAL
AS SHOWN ON PLAN
NON-DETECTABLE
WARNING TAPE,
3 TO 5 MILS IN
THICKNESS, TO BE
INSTALLED APPROX.
24" ABOVE PIPE AND
AT A MINIMUM OF
6" BELOW GRADE
FOR WATERLINES INSTALL
BEDDING STONE TO SPRING LINE
OF PIPE AT A MINIMUM, OR PER
MANUFACTURER'S
RECOMMENDATION
FOR SEWER LINES BEDDING
SHALL BE MIN. 6" ABOVE PIPE
LOCATION OF TRACER WIRE WITH
NON-METALLIC PRESSURE PIPE.
TRACER WIRE NOT REQUIRED FOR
TYPICAL GRAVITY SANITARY SEWER.
SEE DETAIL G-4 FOR ADDITIONAL
REQUIREMENTS
NORMAL SOIL
CONDITIONS
BACKFILL ONLY WITH APPROVED
MATERIAL PER APPLICABLE
LOCALITY OR VDOT STANDARDS
SM-9.5A SURFACE
BM-25.0 BASE
21B SUBBASE
DEPTH VARIES
LIMITS OF OPEN CUT
WIDTH OF TRENCH EXCAVATION
SEEPIPE DIA.
+ 12" EACH SIDE
4"CONDITIONS)
(6" IN ROCK
NOTE
#8#8
NOTE
SEE
1.BEDDING, HAUNCHING AND INITIAL BACKFILL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THIS
DETAIL AND MANUFACTURER'S RECOMMENDATION.
2.ALL PVC PIPE SHALL BE BEDDED IN COMPACTED VDOT #57 OR #58 STONE.
3.IN VDOT ROW, THE CONTRACTOR SHALL REPLACE THE OPEN CUT WITH A MINIMUM TOP COURSE OF
1.5" (MINIMUM) VDOT SM-9.5A, BASE COURSE OF 6" VDOT BM-25.0, AND SUBBASE OF 10" VDOT 21B, OR
AS REQUIRED BY VDOT. IN ROANOKE CITY, CONTRACTOR SHALL REPLACE PAVEMENT AS REQUIRED
BY CITY OF ROANOKE RIGHT OF WAY EXCAVATION AND RESTORATION STANDARDS, LATEST EDITION.
4.ALL CONSTRUCTION WITHIN THE PUBLIC RIGHT-OF-WAY SHALL BE AS SPECIFIED BY VDOT OR
APPLICABLE LOCALITY.
5.PRIOR TO CONSTRUCTION, CONTRACTOR IS RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS
FROM VDOT AND/OR APPLICABLE LOCALITY.
6.IN AREAS SUBJECTED TO VEHICULAR TRAFFIC, BEDDING STONE AND FILL SHALL BE PLACED IN 6"
LIFTS AND SHALL BE COMPACTED TO AT LEAST 95% OF MAXIMUM DENSITY AS DETERMINED BY ASTM
D 698.
7.ALL SEWER LINE PIPE SHALL BE BEDDED IN COMPACTED GRANULAR MATERIAL. BEDDING
REQUIREMENTS FOR DUCTILE SEWER LINE ARE DEPENDENT ON MANUFACTURER'S BEDDING
CRITERIA.
8.BENCHCUT ON EACH SIDE OF PAVEMENT: CITY OF ROANOKE = 12"; VDOT RIGHT-OF-WAY = 6".
9.ALL EXCAVATIONS SHALL COMPLY WITH OSHA TECHNICAL MANUAL, CHAPTER 2, TITLED
"EXCAVATIONS: HAZARD RECOGNITION IN TRENCHING AND SHORING."
10.THE TRACER WIRE SHALL BE PLACED ALONG THE LOWER QUADRANT OF THE PIPE. THE WIRE SHALL
NOT TOUCH THE PIPE, BUT SHALL BE A MAXIMUM OF 6" FROM THE PIPE. NON-METALLIC SPACERS
MAY BE USED TO MAINTAIN A SET DISTANCE FROM THE UTILITY.
BEDDING: FOR WATERLINES, INSTALL BEDDING STONE TO SPRING LINE OF PIPE AT A MINIMUM, OR PER
MANUFACTURER'S RECOMMENDATION, FOR SEWER LINES, BEDDING SHALL BE MINIMUM 6" ABOVE PIPE.
LOCATION OF TRACE WIRE WITH
NON-METALLIC PRESSURE PIPE.
TRACER WIRE NOT REQUIRED FOR
TYPICAL GRAVITY SANITARY SEWER.
SEE DETAIL G-4
1.ALL PAVEMENT MARKINGS DAMAGED OR DESTROYED BY TRENCH EXCAVATION ACTIVITY SHALL BE
REPLACED BY THE PERMITEE PER VDOT SPECIFICATIONS.
2.ALL PVC PIPE SHALL BE BEDDED IN COMPACTED VDOT #57 OR #58 STONE.
3.THIS DETAIL FOR HIGHWAYS WITH EXISTING ASPHALT CONCRETE PAVEMENT SECTIONS.
4.THE EXTENT OF PAVEMENT RESTORATION FOR ALL OTHER PAVEMENT CUTS SHALL BE DETERMINED
BY THE DISTRICT ADMINISTRATOR'S DESIGNEE.
5.** WIDTH OF TRAVEL LANE MINIMUM FULL PAVEMENT WIDTH FOR OPEN CUT TRENCHING ALONG ROAD
CENTERLINE OR 25' (MINIMUM) FOR PERPENDICULAR CROSSINGS.
6.THE TRACER WIRE SHALL BE PLACED ALONG THE LOWER QUADRANT OF THE PIPE. THE WIRE SHALL
NOT TOUCH THE PIPE, BUT SHALL BE A MAXIMUM OF 6" FROM THE PIPE. NON-METALLIC SPACERS
MAY BE USED TO MAINTAIN A SET DISTANCE FROM THE UTILITY.
01/01/12 01/01/12 01/01/12
FOR WATERLINES PROVIDE
BEDDING STONE TO SPRING LINE
OF PIPE AT A MINIMUM,
OR PER MANUFACTURER'S
RECOMMENDATION
PIPELINE
SIZE & MATERIAL
AS SHOWN ON PLAN
SEE BEDDING NOTE BELOW
NON-DETECTABLE
WARNING TAPE,
3 TO 5 MILS IN
THICKNESS, TO BE
INSTALLED APPROX.
24" ABOVE AND
AT A MINIMUM OF
6" BELOW GRADE
(ALL PIPE)
BACKFILL ONLY WITH APPROVED
MATERIAL PER APPLICABLE
LOCALITY OR VDOT STANDARDS
LOCATION OF TRACE WIRE WITH
NON-METALLIC PRESSURE PIPE.
TRACER WIRE NOT REQUIRED FOR
TYPICAL GRAVITY SANITARY SEWER.
SEE DETAIL G-4 FOR ADDITIONAL
REQUIREMENTS.
NON-DETECTABLE WARNING TAPE,
3 TO 5 MILS IN THICKNESS, TO BE
INSTALLED APPROX. 24" ABOVE
PIPE AND AT A MINIMUM OF 6"
BELOW GRADE
EXISTING PAVEMENT
SECTION
Item # 4D
Date: 8-11-2021
AT A REGULAR MEETING OF THE PLANNING COMMISSION OF THE CITY OF
SALEM, VIRGINIA held in Council Chambers of City Hall, 114 North Broad Street,
Salem, VA 24153
AGENDA ITEM: Major Subdivision
Consider the request for preliminary and final approval
of proposed subdivision plat and subdivision plan filed
by Virginia Valley Properties, LLC, property
owner/developer, for a 0.72 acre tract known as the
Calhoun Townhomes.
SUBMITTED BY: Benjamin W. Tripp, AICP, CEcD, City Planner
SUMMARY OF INFORMATION:
SITE CHARACTERISTICS:
Zoning: RMF Residential Multi-Family District
Existing Use: Vacant (house razed 2020)
This plat would create 7 new lots (6 townhomes, 1 common are lot) for the
Calhoun Townhomes. Parking will be at the rear of the townhomes to include
garages. The stormwater management area will be located within the common
area lot.
STAFF RECOMMENDATION:
This plat meets the City of Salem Subdivision Ordinance, and the Subdivision Plan
has been approved by staff. Staff recommends approval.
W
.
C
A
L
H
O
U
N
S
T
R
E
E
T
S 03°09'00" E 131.02'
S1
4
°
0
4
'
0
0
"
E
17
.
4
8
'
N
7
6
°
2
7
'
0
0
"
E
1
9
8
.
0
2
'
S
7
6
°
4
3
'
0
0
"
W
2
1
7
.
1
6
'
N 01°43'00" W 136.31'
CHESTNUT
STREET
18' ALLEY
RA
D
I
U
S
=
1
5
.
0
0
'
TA
N
G
E
N
T
=
1
2
.
1
8
'
AR
C
L
E
N
G
T
H
=
2
0
.
4
6
'
DE
L
T
A
=
7
8
°
0
8
'
5
8
"
CH
O
R
D
=
1
8
.
9
1
'
CH
O
R
D
B
E
A
R
I
N
G
=
N
3
7
°
2
1
'
3
3
"
E
2
7
.
1
4
'
3
6
.
0
9
'
2
5
.
1
6
'
2
5
.
1
6
'
2
5
.
1
6
'
2
5
.
1
6
'
3
4
.
1
4
'
S 03°09'00" E 86.68'
S
7
6
°
4
3
'
0
0
"
W
1
7
4
.
9
0
'
N 01°43'00" W 86.14'
N 03°09'00" W 86.51'
N 03°09'00" W 86.39'
N 03°09'00" W 86.27'
N 03°09'00" W 86.15'
N 03°09'00" W 86.03'
3
6
.
0
6
'
2
5
.
1
4
'
2
5
.
1
4
'
2
5
.
1
4
'
2
5
.
1
4
'
3
8
.
2
6
'
3
0
.
0
0
'
61.00'
1
0
.
0
0
'
NEW 10' ACCESS
EASEMENT
LO
T
A
1
3,
1
4
5
S
Q
.
F
T
.
LOT A2
2,131 SQ.FT.
LOT A3
2,134 SQ.FT.
LOT A4
2,137 SQ.FT.
LOT A5
2,140 SQ.FT.
LOT A6
3,074 SQ.FT.
LO
T
A
-
CO
M
M
O
N
A
R
E
A
16
,
6
0
5
S
Q
.
F
T
.
AR
C
L
E
N
G
T
H
=
2
.
0
0
'
AR
C
L
E
N
G
T
H
=
1
8
.
4
6
'
2
4
.
7
5
'
2
4
.
7
5
'
2
4
.
7
5
'
2
4
.
7
5
'
3
5
.
5
0
'
V
A
R
I
E
S
V
a
r
i
a
b
l
e
R
/
W
W
E
S
T
B
U
R
W
E
L
L
S
T
R
E
E
T
50' R/W
Item # 4E
Meeting Date: 8-11-21
AT A REGULAR MEETING OF THE PLANNING COMMISSION OF THE CITY OF SALEM,
VIRGINIA HELD AT COUNCIL CHAMBERS, CITY HALL, 114 NORTH BROAD STREET,
SALEM, VIRGINIA
AGENDA ITEM: Salem Historic Registry
Consider petition from JASS Properties, Inc., for inclusion in the
Salem Historic Registry of the property located at 401 South
Market Street (Tax Map # 145-10-2).
SUBMITTED BY: Benjamin W. Tripp, AICP, CEcD, City Planner
SUMMARY OF INFORMATION:
This building was originally erected in 1918 for Dr. William Rufus Brown, an important figure
in Salem’s African-American Water Street community, and the town’s only African-American
doctor at the time. Dr. Brown was also an active member of the John Wesley Methodist
Church, the NAACP, YMCA, and the Salem/Roanoke County Civic League. He also helped
to build Carver High School.
The building later served as “Mae’s Inn”, a prominent restaurant in Salem’s then segregated
African-American community owned by Ethel May Myers Whitfield. After the restaurant was
sold in the late 1950’s it became a Masonic lodge (Salem Lodge 120).
On June 17, 2021 this property the Virginia Department of Historic Resources deemed this
property to be eligible for nomination to the National Register of Historic Places and the
Virginia Landmarks Register.
FISCAL IMPACT:
Adding this property to the Salem Historic Registry will allow regulatory flexibility and
encourage the preservation and productive use of the property.
STAFF RECOMMENDATION: