Loading...
HomeMy WebLinkAbout11/10/2021 - Planning Commission - Agenda -RegularPlanning Commission Meeting AGENDA Wednesday, November 10, 2021, 7:00 PM Council Chambers, City Hall, 114 North Broad Street, Salem, Virginia WORK SESSION 1.Call to Order 2.New Business A.Discussion items from the November Meeting Discussion of items from the November 10, 2021, regular session agenda. B.Discussion of Bylaws Continue the discussion of proposed bylaws. 3.Adjournment REGULAR SESSION 1.Call to Order 2.Pledge of Allegiance 3.Consent Agenda A.Minutes Consider acceptance of the minutes from the October 13, 2021, work session and regular meeting. 4.New Business A.Simms Farm Section 2 Consider the request of Simms Property, LLC., property owner/developer for approval of the amended subdivision plan for a 4.549 acre tract known as Simms Farm Section 2. 5.Adjournment City Council meeting, November 29, 2021, 6:30 p.m. Community Room, Salem Civic Center, 1001 Roanoke Boulevard W Planning Commission Meeting MINUTES Wednesday, October 13, 2021, 7:00 PM Work Session 6:00PM Council Chambers Conference Room, City Hall, 114 North Broad Street WORK SESSION 1.Call to Order A work session of the Planning commission of the City of Salem, Virginia, was held in Council Chambers Conference Room, City Hall, 114 North Broad Street, at 6:00 p.m. on October 13, 2021; there being present said Commission members to wit: Vicki G. Daulton, Chair; Denise P. King, Vice Chair; Reid A. Garst, II; Jackson Beamer, and Neil L. Conner; together with H. Robert Light, Assistant City Manager and Deputy Executive Secretary, ex officio member of said Commission; Charles E. Van Allman, Jr., Director of Community Development; Mary Ellen Wines, Zoning Administrator; and Jim H. Guynn, Jr., City Attorney; and the following business was transacted: Chair Daulton called the meeting to order at 6:00 p.m. and reported that this date, place, and time had been set in order for the Commission to hold a work session. Benjamin Tripp, former City Planner was also present. 2.New Business A.Discussion items from the October Meeting Discussion of items from the October 13, 2021, regular session agenda. A discussion was held regarding the request of .Com Properties 8, LLC, property owner, for rezoning the property located at 1796 Apperson Drive (a portion of Tax Map #257-2-1.1) from HBD Highway Business District to LM Light Manufacturing District. Member Garst would prefer commercial; Member Conner likes industrial; Vice Chair King doesn't like looking at empty spaces. Member Garst noted that other uses are allowed. A discussion was held regarding the approval of the proposed subdivision plan and W preliminary and final subdivision plat for a 4.549-acre tract known as Simms Farm Section 2. Mr. Van Allman noted that trails will be added to next submittal for entire site. A discussion was held regarding the approval of the amended subdivision plan filed by Simms Property, LLC, property owner/developer, for a 7.564-acre tract known as Simms Farm Section 1. Mr. Van Allman noted that the plat follows the change in plan from last month. The Commission does not want to move future meetings to the Salem Civic Center. 4.Adjournment A discussion was held regarding moving future Planning Commission meetings to the Salem Civic Center, and the Commission does not want to move the meetings. Chair Daulton inquired if there were any other items for discussion and hearing none, adjourned the work session at 6:40 p.m. REGULAR SESSION 1.Call to Order A regular meeting of the Planning Commission of the City of Salem, Virginia, was held after due and proper notice in the Council Chambers, City Hall, 114 North Broad Street, Salem, Virginia, at 7:00 p.m. on October 13, 2021. Notice of such hearing was published in the September 30 and October 7, 2021, issues of the "Salem Times Register," a newspaper published and having general circulation in the City of Salem. All adjacent property owners were notified via the U.S. Postal Service. The Commission, constituting a legal quorum, presided together with Jim H. Guynn, Jr., City Attorney; H. Robert Light, Assistant City Manager and Deputy Executive Secretary, ex officio member of said Commission, to wit; Charles E. Van Allman, Jr., Director of Community Development; and Mary Ellen Wines, Zoning Administrator; and the following business was transacted: Chair Daulton called the meeting to order at 7:00 p.m. 2.Pledge of Allegiance 3.Consent Agenda m A.Minutes Consider acceptance of the minutes from the September 15, 2021, work session and regular meeting. Neil Conner motioned Consider acceptance of the minutes from the September 15, 2021, work session and regular meeting.. Jackson Beamer seconded the motion. Ayes: Beamer, Conner, Daulton, Garst, King 4.New Business A.Amendment to the Zoning Ordinance Hold public hearing to consider the request of .Com Properties 8, LLC, property owner, for rezoning the property located at 1796 Apperson Drive (a portion of Tax Map # 257-2-1.1) from HBD Highway Business District to LM Light Manufacturing District. Staff noted the following: The subject property consists of a 6.71-acre parcel located southwest of the intersection of Dillard Drive and Apperson Drive. The request is to rezone a portion of the property. Only 1.12 acres is considered for this request. The portion of the parcel is vacant as there has not been a permanent business to occupy this portion since Food Lion closed in 2014. The 1.12-acre portion will be subdivided from the parent parcel. There will be cross access agreements between the two parcels for access, parking, etc. Lewis Gale would like to move from their current location at 2141 Apperson Drive. They anticipate one to two employees on site at a time with one to two box trucks for distribution per day. Deliveries are expected to also be approximately two a day. This location will be a center for multiple locations for Lewis Gale. There will be security systems with cameras as well as their security service making rounds. There will be some medication on site, but no narcotics. There will be no additional exterior lighting. Staff recommends approval of the request. Ben Crew, Balzer & Associates, 1208 Corporate Circle, Roanoke, VA, appeared before the Commission on behalf of the property owner; he stated that the request is in response to a request a couple months ago; Lewis Gale would like to have warehouse and storage in the former Food Lion section of the retail center. The previous location was down the street where Layman Candy Company is purchasing the property; therefore, they need to find a new location. The rezoning is requested b to facilitate the use. Vice Chair King questioned the relationship of Dominion Air & Machinery Company; and Mr. Crew stated that Dominion Air & Machinery Company handles the management portion of the various .Com properties for the property owner, Richard Bishop. Chair Daulton questioned why the property needs to be rezoned. Mr. Crew stated that based on discussions with city staff, the use is identified in the zoning ordinance as warehouse and storage, which is not allowed in the HBD Highway Business District zoning classification; Lewis Gale has many medical facilities around the region and needs a clearing house or a place to have "stuff" (i.e. waiting room chairs, medical equipment, miscellaneous items); the maintenance group will use it as a hub to receive deliveries, to take deliveries, to go get things that various hospitals or clinics need and use it as a true warehouse/storage area to support its facilities. No other person(s) appeared related to the request. Neil Conner motioned approval of the request of .Com Properties 8, LLC, property owner, for rezoning the property located at 1796 Apperson Drive (a portion of Tax Map #257-2-1.1) from HBD Highway Business District to LM Light Manufacturing District. Denise King seconded the motion. Ayes: Beamer, Conner, Daulton, King Nays: Garst B.Simms Farm Section 2 Consider the request of Simms Property, LLC., property owner/developer for approval of the proposed subdivision plan and preliminary and final subdivision plat for a 4.549 acre tract known as Simms Farm Section 2. Staff noted that this plat would create 12 new lots (88-99) for Phase 2 of the "Simms Farm" subdivision. This phase includes residential lots, an open space lot, and a new street. The lots are located along and to the west of Diamond Road, north of the intersection of Diamond Road and Upland Drive. The plat meets the requirements of the Subdivision Ordinance. Both the plat and plan have been reviewed by City Staff and approval is recommended with any field revisions to be approved administratively by staff. Neil Conner motioned approval of the request of Simms Property, LLC, property owner/developer, for approval of the proposed subdivision plan and preliminary and f final subdivision plat for a 4.549-acre tract known as Simms Farm Section 2. Jackson Beamer seconded the motion. Ayes: Beamer, Conner, Daulton, Garst, King C.Simms Farm Section 1 Consider the request for approval of the amended subdivision plat filed by Simms Property, LLC., property owner/developer, for a 7.564 acre tract known as Simms Farm Section 1. Staff noted that Section 1 plans were modified and approved by this body on September 15, 2021. The modifications included moving the stormwater pond into an area where it can better collect and detain the runoff from the development. There were no changes to the layout, or utilities. The only changes were to the stormwater pond and associated easements. This plat amendment meets the requirements and recommends approval. Denise King motioned approval of the request for approval of the amended final subdivision plat filed by Simms Property, LLC., property owner/developer, for a 7.564-acre tract known as Simms Farm Section 1.. Neil Conner seconded the motion. Ayes: Beamer, Conner, Daulton, Garst, King 5.Adjournment On motion by Member Garst, meeting was adjourned at 7:10 p.m. City Council meeting, October 25, 2021, 6:30 p.m. Community Room, Salem Civic Center, 1001 Roanoke Boulevard R Item # 4A Date: 11-10-2021 AT A REGULAR MEETING OF THE PLANNING COMMISSION OF THE CITY OF SALEM, VIRGINIA held in Council Chambers of City Hall, 114 North Broad Street, Salem, VA 24153 AGENDA ITEM: Simms Farm Section 2 Amended Subdivision Plan Consider the request of Simms Property, LLC., property owner/developer for approval of the amended subdivision plan for a 4.549-acre tract known as Simms Farm Section 2. SUBMITTED BY: Mary Ellen Wines, CZA CFM Zoning Administrator SUMMARY OF INFORMATION: Although the previous plan submitted did meet all requirements, staff recommended to the developer during the staff review process that the storm drainpipe between lots 94 and 95 be extended so ensure the water discharge would not impact the house that will be constructed on lot 94. After the October Planning Commission meeting, the developer agreed and submitted amended plans. STAFF RECOMMENDATION: This plan has been reviewed by City Staff and approval is recommended with any field revisions to be approved administratively by staff. 7 SHEET INDEX CITY OF SALEM, VIRGINIA SIMMS FARMSECTION 2 UPLAND DRIVE LEGEND ABBREVIATIONS C1 COVER C2 OVERALL PROPERTY MAP C3 EXISTING CONDITIONS & DEMO PLAN C4 LAYOUT & UTILITY PLAN C5 GRADING PLAN C6.1 E.S.C. PLAN C6.2 E.S.C. NOTES C6.3 E.S.C. DETAILS C7.1 ROAD PROFILE C7.2 UTILITY PROFILES C7.3 SIGHT DISTANCE PROFILE C8 NOTES C9.1 DETAILS C9.2 WESTERN VA REGIONAL DETAILS I C9.3 WESTERN VA REGIONAL DETAILS II PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 3 9 : 0 6 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 N/A SI M M S F A R M S E C T I O N 2 CO V E R UP L A N D D R I V E CI T Y O F S A L E M , V I R G I N I A C1 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021ENGINEERS NOTES: VICINITY MAP NTS GENERAL NOTES STORM SEWER/SWM/SWQ AS-BUILT NOTES: 8 5 2 1 3 4 6 8 7 9 35 34 38 3941 57 40 43 42 61 59 58 60 65 68 66 62 63 67 73 71 69 70 76 72 7975 74 80 77 64 83 85 81 82 84 86 88 87 91 89 94 95 96 97 93 100 90 92 99 101 103 104 106 78 98 105 10 11121314151617 1819 20 21 22 23 24 25 26 27 28 29 30 31 3233 130131 119 36 37 107 102 108 109 110 111 112 113 116 117 118 120 121 122 123 124 125 126127129132133134 136 137 138 4445 46 47 48 49 50 51 52 53 54 55 56 115 139 128 135 114 PHASE 1 OPEN SPACE 1.24 AC. PHASE 1 OPEN SPACE 0.49 AC. PHASE 2 OPEN SPACE 1.02 AC. PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 3 9 : 3 5 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 1"=100' SI M M S F A R M S E C T I O N 2 OV E R A L L P R O P E R T Y M A P UP L A N D D R I V E CI T Y O F S A L E M , V I R G I N I A C2 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021  PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 4 0 : 3 3 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 1" = 30' SI M M S F A R M S E C T I O N 2 EX I S T I N G C O N D I T I O N S & D E M O P L A N UP L A N D D R I V E CI T Y O F S A L E M , V I R G I N I A C3 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021 10 PROPO S E D R O A D B LOT 94 LOT 93 LOT 92 LOT 95 LOT 96 LOT 97 LOT 98 LOT 99 LOT 100 LOT 87 LOT 88 LOT 89 LOT 90 LOT 91 LOT 101 LOT 102 LOT 86 PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 4 0 : 5 0 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 1" = 30' SI M M S F A R M S E C T I O N 2 LA Y O U T & U T I L I T Y P L A N UP L A N D D R I V E CI T Y O F S A L E M , V I R G I N I A C4 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021 11 PROPO S E D R O A D B LOT 94 LOT 93 LOT 92 LOT 95 LOT 96 LOT 97 LOT 98 LOT 99 LOT 100 LOT 87 LOT 88 LOT 89 LOT 90 LOT 91 LOT 101 LOT 102 LOT 86 PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 4 1 : 3 2 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 1" = 30' SI M M S F A R M S E C T I O N 2 GR A D I N G P L A N UP L A N D D R I V E CI T Y O F S A L E M , V I R G I N I A C5 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021 DITCH C DETAIL N.T.S. 2YR VELOCITY = 6.32 fps 10YR DEPTH = 0.66' EC-3, TYPE B LINING DITCH B DETAIL N.T.S. 2YR VELOCITY = 2.24 fps 10YR DEPTH = 0.58' EC-2 LINING DITCH A (OMITTED) 12 PROPO S E D R O A D B LOT 94 LOT 93 LOT 92 LOT 95 LOT 96 LOT 97 LOT 98 LOT 99 LOT 100 LOT 87 LOT 88 LOT 89 LOT 90 LOT 91 LOT 101 LOT 102 LOT 86 LIMITS OF DISTURBANCE ±4.80 AC. PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 4 1 : 5 8 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 1"=30' SI M M S F A R M S E C T I O N 2 E. S . C . P L A N UP L A N D D R I V E CI T Y O F S A L E M , V I R G I N I A C6.1 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021 13 PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 4 2 : 1 4 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 N/A SI M M S F A R M S E C T I O N 2 E. S . C . N O T E S UP L A N D D R CI T Y O F S A L E M , V I R G I N I A C6.2 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021 CONCRETE TRUCK WASHOUT DETAIL NTS TEMPORARY DIVERSION DIKE DD 14 PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 4 2 : 2 8 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 N/A SI M M S F A R M S E C T I O N 2 E. S . C . D E T A I L S UP L A N D D R CI T Y O F S A L E M , V I R G I N I A C6.3 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021 FOR INSTALLATION OF TREATMENT - 2 SOIL STABILIZATION MATTING STAKES, STAPLES, & PINS TYPICAL TREATMENT - 1 (SOIL STABILIZATION BLANKET) INSTALLATION CRITERIA BLANKET MATTINGB/M CONSTRUCTION ENTRANCETEMPORARY GRAVELCE SF CONSTRUCTION OF A SILT FENCE SPECIFIC APPLICATION GRAVEL CURB INLET SEDIMENT FILTERIP SEDIMENT TRAP #1 DETAIL TEMPORARY SEDIMENT TRAP #1 SPECIFICATIONSST OUTLET PROTECTIONOP SEDIMENT TRAP #1 DETAIL TEMPORARY SEDIMENT TRAP #2 SPECIFICATIONSST FERTILIZER SPECIFICATIONS AND RATES FOR MANAGEMENT PERMANENT SEEDING SPECIFICATIONSPS TEMPORARY SEEDING SPECIFICATIONSTS 15 PROPOSED PUBLIC ROAD B PROFILE PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 4 2 : 5 2 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 AS SHOWN SI M M S F A R M S E C T I O N 2 RO A D P R O F I L E UP L A N D D R CI T Y O F S A L E M , V I R G I N I A C7.1 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021 PAVEMENT JOINT DETAIL ON-SITE CONC. SIDEWALK ROAD B PAVEMENT SECTION 16 PROPOSED SANITARY PROFILE PROPOSED STORM 18-14 PROFILE 14 17 15 16 18 19 20 21 22 23 24 14A 14B PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 4 3 : 3 9 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 AS SHOWN SI M M S F A R M S E C T I O N 2 UT I L I T Y P R O F I L E S UP L A N D D R CI T Y O F S A L E M , V I R G I N I A C7.2 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021 17 DIAMOND RD ENTRANCE SIGHT DISTANCE PROFILE PROPO S E D R O A D B LOT 94 LOT 95 LOT 96 LOT 87 LOT 88 LOT 89 LOT 90 LOT 91 LOT 86 PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 4 4 : 2 2 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 AS SHOWN SI M M S F A R M S E C T I O N 2 SI G H T D I S T A N C E P R O F I L E UP L A N D D R CI T Y O F S A L E M , V I R G I N I A C7.3 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021 18 PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 4 4 : 4 4 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 N/A SI M M S F A R M S E C T I O N 2 NO T E S UP L A N D D R CI T Y O F S A L E M , V I R G I N I A C8 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021 . 19 PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 4 4 : 5 9 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 N/A SI M M S F A R M S E C T I O N 2 DE T A I L S UP L A N D D R CI T Y O F S A L E M , V I R G I N I A C9.1 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021 S.W.M. POND #2 DETAIL 20 PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 4 5 : 2 0 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 N/A SI M M S F A R M S E C T I O N 2 WE S T E R N V I R G I N I A R E G I O N A L D E T A I L S I UP L A N D D R CI T Y O F S A L E M , V I R G I N I A C9.2 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021 3' MIN. 1. BEDDING, HAUNCHING AND INITIAL BACKFILL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THIS DETAIL AND MANUFACTURER'S RECOMMENDATION. 2. ALL PVC PIPE SHALL BE BEDDED IN COMPACTED VDOT #57 OR #68 STONE, OR CRUSHER RUN. 3. IN AREAS SUBJECTED TO VEHICULAR TRAFFIC, BEDDING STONE AND FILL SHALL BE PLACED IN 6" LIFTS FROM BOTTOM OF TRENCH TO 1' ABOVE THE PIPE AND THE REMAINING SHALL BE PLACED IN 10" LIFTS AND SHALL BE COMPACTED TO AT LEAST 90% OF MAXIMUM DENSITY AS DETERMINED BY ASTM D 698. 4. BEDDING REQUIREMENTS FOR DUCTILE IRON WATER LINE ARE DEPENDENT ON MANUFACTURER'S BEDDING CRITERIA. 5. ALL EXCAVATIONS SHALL COMPLY WITH OSHA TECHNICAL MANUAL, CHAPTER 2, TITLED "EXCAVATIONS: HAZARD RECOGNITION IN TRENCHING AND SHORING." 6. THE TRACER WIRE SHALL BE PLACED ALONG THE LOWER QUADRANT OF THE PIPE. THE WIRE SHALL NOT TOUCH THE PIPE, BUT SHALL BE A MAXIMUM OF 6" FROM THE PIPE. NON-METALLIC SPACERS MAY BE USED TO MAINTAIN A SET DISTANCE FROM THE UTILITY. (4" MIN. - 6" IN ROCK CONDITIONS) FINISHED GRADE PIPE SIZE & MATERIAL AS SHOWN ON PLAN NON-DETECTABLE WARNING TAPE, 3 TO 5 MILS IN THICKNESS, TO BE INSTALLED APPROX. 24" ABOVE PIPE AND AT A MINIMUM OF 6" BELOW GRADE (ALL PIPE) FOR WATERLINES INSTALL BEDDING STONE TO SPRING LINE OF PIPE AT A MINIMUM, OR PER MANUFACTURER'S RECOMMENDATION FOR SEWER LINES BEDDING SHALL BE MIN. 6" ABOVE PIPE LOCATION OF TRACER WIRE WITH NON-METALLIC PRESSURE PIPE. TRACER WIRE NOT REQUIRED FOR TYPICAL GRAVITY SANITARY SEWER. SEE DETAIL G-4 FOR ADDITIONAL REQUIREMENTS NORMAL SOIL CONDITIONS BACKFILL ONLY WITH APPROVED MATERIAL PER APPLICABLE LOCALITY OR VDOT STANDARDS 08/01/15 WIDTH OF TRENCH EXCAVATION PIPE DIA. + 6" EACH SIDE (MINIMUM) SURFACE MIX ASPHALT BASE MIX ASPHALT SUBBASE DEPTH VARIES LIMITS OF OPEN CUT SEE 4"CONDITIONS) (6" IN ROCK NOTE#8#8NOTESEE 1. BEDDING, HAUNCHING AND INITIAL BACKFILL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THIS DETAIL AND MANUFACTURER'S RECOMMENDATION. 2. ALL PVC PIPE SHALL BE BEDDED IN COMPACTED VDOT #57 OR #68 STONE. 3. IN VDOT ROW, THE CONTRACTOR SHALL REPLACE THE PAVEMENT AS REQUIRED AND SPECIFIED BY VDOT. IN ROANOKE CITY, CONTRACTOR SHALL REPLACE PAVEMENT AS REQUIRED BY CITY OF ROANOKE RIGHT OF WAY EXCAVATION AND RESTORATION STANDARDS, LATEST EDITION. 4. ALL CONSTRUCTION WITHIN THE PUBLIC RIGHT-OF-WAY SHALL BE AS SPECIFIED BY VDOT OR APPLICABLE LOCALITY. 5. PRIOR TO CONSTRUCTION, CONTRACTOR IS RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS FROM VDOT AND/OR APPLICABLE LOCALITY. 6. IN AREAS SUBJECTED TO VEHICULAR TRAFFIC, BEDDING STONE AND FILL SHALL BE PLACED IN 6" LIFTS AND SHALL BE COMPACTED TO AT LEAST 95% OF MAXIMUM DENSITY AS DETERMINED BY ASTM D 698. 7. ALL SEWER LINE PIPE SHALL BE BEDDED IN COMPACTED GRANULAR MATERIAL. BEDDING REQUIREMENTS FOR DUCTILE SEWER LINE ARE DEPENDENT ON MANUFACTURER'S BEDDING CRITERIA. 8. BENCH CUT ON EACH SIDE OF PAVEMENT SHALL BE IN ACCORDANCE WITH VDOT OR APPLICABLE LOCALITY'S SPECIFICATIONS. 9. ALL EXCAVATIONS SHALL COMPLY WITH OSHA TECHNICAL MANUAL, CHAPTER 2, TITLED "EXCAVATIONS: HAZARD RECOGNITION IN TRENCHING AND SHORING." 10. THE TRACER WIRE SHALL BE PLACED ALONG THE LOWER QUADRANT OF THE PIPE. THE WIRE SHALL NOT TOUCH THE PIPE, BUT SHALL BE A MAXIMUM OF 6" FROM THE PIPE. NON-METALLIC SPACERS MAY BE USED TO MAINTAIN A SET DISTANCE FROM THE UTILITY. BEDDING: FOR WATERLINES, INSTALL BEDDING STONE TO SPRING LINE OF PIPE AT A MINIMUM, OR PER MANUFACTURER'S RECOMMENDATION. FOR SEWER LINES, BEDDING SHALL BE MINIMUM 6" ABOVE PIPE. LOCATION OF TRACER WIRE WITH NON-METALLIC PRESSURE PIPE. TRACER WIRE NOT REQUIRED FOR TYPICAL GRAVITY SANITARY SEWER. SEE DETAIL G-4 08/01/15 PIPE SIZE & MATERIAL AS SHOWN ON PLAN SEE BEDDING NOTE BELOW NON-DETECTABLE WARNING TAPE, 3 TO 5 MILS IN THICKNESS, TO BE INSTALLED APPROX. 24" ABOVE PIPE AND AT A MINIMUM OF 6" BELOW GRADE (ALL PIPE) BACKFILL ONLY WITH APPROVED MATERIAL PER APPLICABLE LOCALITY OR VDOT STANDARDS EXISTING PAVEMENT SECTION WIDTH OF TRENCH EXCAVATION PIPE DIA. + 6" EACH SIDE ( MINIMUM) 09/06/16 GROUND WIRE TO GROUNDING SOURCE GROUND BAR 1. TRACER WIRES SHALL BE INSTALLED USING MANHOLES, TRACER WIRE ACCESS BOXES, VALVE BOXES OR VAULTS, WATER METERS AND FIRE HYDRANTS AS ACCESS POINTS. 2. FOR WATER AND SEWER INSTALLED BY OPEN TRENCHING, HORIZONTAL DIRECTIONAL DRILLING, OR PIPE BURSTING, TRACER WIRE SHALL BE NEPTCO TRACE-SAFE WATER BLOCKING TRACER WIRE OR APPROVED EQUAL. 3. SPLICES SHALL ONLY BE MADE WITH GEL FILLED CONNECTORS DESIGNED FOR WIRE WITH A WOVEN POLYESTER FIBER CORE SUCH AS NEPTCO TRACE-SAFE WATER BLOCKING CONNECTORS OR APPROVED EQUAL. SPLICES SHALL BE MADE IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. CONTRACTOR WILL BE RESPONSIBLE FOR ENSURING CONTINUITY AT ALL SPLICE LOCATIONS. 4. WHERE HDPE PIPE IS INSTALLED WITHOUT STEEL CASING PIPE, SUCH AS A DIRECTIONALLY DRILLED CROSSINGS, AND CONNECTED TO DUCTILE IRON PIPE ON EACH END, TRACER WIRE SHALL BE INSTALLED ALONG FULL LENGTH OF HDPE PIPE WITH AN ACCESS POINT INSTALLED AT EACH HDPE/DUCTILE IRON TRANSITION. TRACER WIRE SHALL BE CONNECTED TO THE ACCESS POINT IN ACCORDANCE WITH THIS DETAIL. ANY TRANSITION FROM DUCTILE IRON MAIN TO NON-DUCTILE IRON MAIN SHALL HAVE AN ACCESS POINT TO BEGIN TRACER WIRE. 5. AS-BUILTS SHALL SHOW TRACER WIRE(S) LOCATION AND ACCESS POINT(S), ALONG WITH BUTT SPLICE LOCATIONS. 6. THE TRACER WIRE SHALL BE PLACED ALONG THE LOWER QUADRANT OF THE PIPE. THE WIRE SHALL NOT TOUCH THE PIPE, BUT SHALL BE A MAXIMUM OF 6" FROM THE PIPE. NON-METALLIC SPACERS MAY BE USED TO MAINTAIN A SET DISTANCE FROM THE UTILITY. 7. WIRE SHALL BE BROUGHT TO THE SURFACE EVERY FIVE-HUNDRED (500) FEET AND PLACED IN A WATER METER BOX OR A DRAINAGE & WATER SOLUTIONS, INC. (OR APPROVED EQUAL) ALL CAST IRON TRACER WIRE ACCESS BOX. 8. THE TRACER WILL BE TESTED BY THE PARTICIPATING UTILITY AS PART OF THE PROJECT'S FINAL ACCEPTANCE. CONTRACTOR WILL BE RESPONSIBLE FOR ENSURING ALL CONTINUITY OF TRACER WIRE. 9. THE GROUND WIRE SHALL BE #6 AWG COPPER WIRE AND SHALL BE OF ADEQUATE LENGTH TO EXTEND A MINIMUM OF (5) FIVE FEET BEYOND THE TOP OF THE STRUCTURE. THE END OF THE GROUND WIRED SHALL CONNECT TO THE GROUND BAR OR LID TERMINAL USING A BURNDY KA6U MECHANICAL TERMINAL LUG. 10.A GROUND ROD SHALL BE INSTALLED AT EACH LOCATION WHERE GROUND WIRE SURFACES AND CONNECTS TO GROUND BAR. GROUND ROD SHALL BE COPPER COATED WITH A MINIMUM DIAMETER OF 5/8" AND SHALL BE BURIED A MINIMUM OF FOUR (4) FEET INTO THE GROUND. 11.THE GROUND BAR SHALL BE STAINLESS STEEL AND SHALL BE ATTACHED USING SS 14" X 114" SS HEX TAPCON. THE FOLLOWING SHALL BE INSTALLED IN (4) FOUR CENTER HOLES: 10-32SS NUTS, #10 SS WASHERS AND 10-32 X 34 SS PHILLIPS. THE FOURTH HOLE SHALL HAVE A BURNDY KA6U MECHANICAL TERMINAL LUG FOR THE #6 AWG GROUND WIRE. THE ASSEMBLY CAN BE ACQUIRED AT RCS INDUSTRIAL SUPPLY, INC. (540-353-0683) - CLAMP RFC-11. THE ENDS OF THE TRACER WIRES SHALL BE PLACED IN THE GROUND BAR AS SHOWN BELOW. 12.IF USING TRACER WIRE ACCESS BOX AS ACCESS POINT, GROUND BAR WILL NOT BE REQUIRED. WIRES SHALL BE CONNECTED AS SHOWN BELOW. TRACER WIRE SHALL BE OF ADEQUATE LENGTH TO EXTEND FIVE (5) FEET ABOVE THE TOP OF ACCESS BOX. 13.TWO WRAPS OF TRACER WIRE SHALL BE WRAPPED SNUGGLY AROUND BASE OF HYDRANT. WIRE SHALL NOT BE LEFT IN A WAY THAT WOULD INTERFERE WITH MOWING AROUND HYDRANT. 14.WHEN USING ALL DUCTILE MAIN, TRACER WIRE FOR SERVICES SHALL BE 12 AWG COPPER TRACER WIRE. TRACER WIRE SHALL HAVE BARE WIRE CONTACT TO DUCTILE MAIN. TRACER WIRE ACCESS BOX LID 3 1/8" LOCATING CLIP (TS19-IL-LC-C) 5' TRACE SAFE LOCATING CLIP (TS19-IL-LC-C) 5' TRACE SAFE 1 1/2" LOCATECLIP UNDERCOVER LOCATECLIP UNDERCOVER 09/06/16 TS19-C TS19-C LOCATE CLIP UNDER COVER LOCATING CLIP (TYP.) (TS19-IL-LC-C) GROUND BAR (TYP.) LOCATING CLIP FRONT VIEW (TS19-IL-LC-C) 1. TRAFFIC BEARING BOX AND LID REQUIRED IN TRAFFIC AREAS (CAPITOL FOUNDRY VB-9*S). 2. SEWER LATERAL AND CLEANOUT PIPING SHALL BE ASTM D3034 SDR 26. SEWER LATERAL FITTINGS SHALL BE OF SAME SDR RATING AS THE SEWER MAIN. SCHEDULE 40 SOLVENT WELD PIPE AND FITTINGS MAY BE USED FOR THE SEWER LATERAL AND CLEANOUT ASSEMBLY WITH APPROVAL FROM THE PARTICIPATING UTILITY. 3. ALL PIPE SHALL BE OF SAME SIZE. 4. NO BENDS ARE ALLOWED IN THE LATERAL FROM THE MAIN TO THE CLEANOUT STACK WYE. (EXCEPT FOR DEEP SEWER, AS SHOWN BELOW). 5. ALL MAIN LINE TAPS ON ACTIVE MAINS SHALL BE PERFORMED BY PARTICIPATING UTILITY. 6. PIPING ON PRIVATE SIDE OF CLEANOUT TO BE INSTALLED PER GOVERNING JURISDICTION REQUIREMENTS. 7. MINIMUM LATERAL SIZE: 4" FOR RESIDENTIAL SERVICE, 6" FOR NON-RESIDENTIAL SERVICE. 8. SEWER CLEANOUTS SHALL BE SAME SIZE AS SEWER LATERAL. 9. MINIMUM COVER FOR ALL SEWER LATERALS SHALL BE THREE (3') FEET. 10.PROPERTY OWNER RESPONSIBLE FOR INSTALLING CLEANOUT ON PROPERTY LINE (IN ACCORDANCE WITH THIS DETAIL) WHEN MAINTENANCE OCCURS. 11.LOWEST SERVED FINISHED FLOOR ELEVATION SHALL BE A MINIMUM OF THREE FEET (3') ABOVE THE TOP OF THE MAIN AT THE POINT WHERE THE SERVICE LATERAL CONNECTS TO THE MAIN. 12.WHEN CONNECTING TO EXISTING LATERAL USE FERNCO FLEXIBLE COUPLING. RIGHT OF WAY OR LIMITS OF EASEMENTPRIVATE PROPERTY FINISHED GRADE CLEAN OUT BOX AND LID (SET TO FINISHED GRADE) 45o WYE (TEE NOT ACCEPTABLE) 1/4" PER 1'- 0" MINIMUM GRADE SOLID GLUE CAP ROUGH GRADE CLEAN-OUT STACK (SEE NOTES #2 & #8) MAX.45o 11.25o OR 22.5o BEND SEWER MAIN SAME AS ABOVE 01/01/14 (SEE NOTE #2) TEE, WYE, TEE/WYE OR COMBINATION OF WYE & 45o BEND FITTINGS SHALL BE SIZED AS REQUIRED 2'-0" MIN. 2'-0" MIN.45o MAX. 45o OR 22.5o BELL & SPIGOT BEND (IF NEEDED) CLEAN-OUT TO EXTEND ABOVE GROUND A MIN. OF 3 FEET DURING INSTALLATION OF MAIN LINE. PLUMBER SHALL CUT STACK TO FINISHED GRADE AS SHOWN WHEN BUILDING SEWER IS CONNECTED TO LATERAL PLASTIC BODY CLEAN-OUT & CAP 4" MINIMUM GRAVEL BEDDING #57 OR EQUIVALENT (SEE NOTE #6) HORIZONTAL SECTION SHALL EXTEND A MINIMUM OF 5' OR AS DIRECTED BY THE PARTICIPATING UTILITY (SEE NOTE #2) 4'-0" GROUT ANNULAR SPACE (TYP. INLET & OUTLET) A BUTYL MASTIC JOINT SEALER OR GASKETS MEETING ASTM C443 AND ASTM C1244 TESTING STANDARD (NO MORTAR) ADJUSTMENT RINGS IF NECESSARY (1'-0" MAX ADJUSTMENT) SEE FRAME & COVER DETAILS A ECCENTRIC CONE HEIGHT VARIES RISER SECTIONS HEIGHT VARIES 8" MIN MANHOLE WITH PRECAST INVERT SERVICE CONNECTION 4'-0"5" Min. (Typ.) 6" Min. BASE HEIGHT VARIES 2'-0" 1. MATERIALS AND FABRICATION IN ACCORDANCE WITH ASTM C478-09. 2. WHEN USED AS SAMPLING MANHOLE FLOW SHALL PASS STRAIGHT THROUGH, i.e., 180 o. 3. STEPS SHALL BE VERTICALLY ALIGNED. FIRST STEP SHALL BE WITHIN 12" OF COVER, BOTTOM STEP SHALL BE WITHIN 24" OF BOTTOM OF MANHOLE. 4. FRAME AND COVER SHALL BE PROPERLY ALIGNED WITH THE 2 FOOT OPENING OF THE MANHOLE STRUCTURE AND BOLTED IN PLACE. 5. FLAT TOP MANHOLES MAY ONLY BE SUBSTITUTED WITH THE PERMISSION OF THE PARTICIPATING UTILITY. 6. FLEXIBLE JOINT MANHOLE CONNECTION SHALL BE AS MANUFACTURED BY PRES-SEAL GASKET CORPORATION OR EQUAL. 7. GROUT ANNULAR SPACE BETWEEN PIPE AND PRECAST MANHOLE ON INSIDE OF MANHOLE. 8. WHEN REPLACING AN EXISTING MANHOLE OR INSTALLING A NEW PRECAST MANHOLE ON AN EXISTING SEWER, A MINIMUM OF SIX FEET (6') OF EXISTING PIPE SHALL BE REMOVED AND REPLACED WITH NEW MATERIAL ON INLET AND OUTLET OF MANHOLE. 9. MANHOLES WHERE THE INVERT IS LOWER THAN THE NORMAL GROUNDWATER ELEVATION (I.E., ALONG CREEKS, RIVERS, LOW-LYING AREAS, ETC.) SHALL HAVE A FULL EXTERIOR COATING AND JOINT WRAP APPLIED IN ADDITION TO JOINT SEALANT. SEE NOTES 10 & 11. 10. IF REQUIRED EXTERIOR VERTICAL WALL SURFACES SHALL BE FACTORY COATED IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATION. COATING SHALL BE HIGH BUILD COAL TAR EPOXY MEETING ASTM D1227. COATING SHALL BE APPLIED IN TWO COATS TO A MINIMUM TOTAL THICKNESS OF 16 MILS. 11. IF REQUIRED ALL MANHOLES SHALL UTILIZE AN EXTERNAL FRAME AND JOINT SEAL AT ALL JOINTS AND AT THE FRAME/CHIMNEYINTERFACE. SEAL SHALL BE MADE OF EPDM RUBBER INACCORDANCE WITH ASTM D412 OR POLYOLEFIN BACKED EXTERIOR JOINT WRAP IN ACCORDANCE WITH ASTM E-1745, C-877, AND C-990. EDM SEAL SHALL HAVE A MINIMUM THICKNESS OF 60 MILS. POLYOLEFIN BACKED EXTERIOR JOINT WRAP SHALL HAVE A BACKING BAND ELEMENT WITH MINIMUM THICKNESS OF 4 MILS. AND BUTYL ROLLER ADHESIVE WITH MINIMUM THICKNESS OF 60 MILS. SEAL SHALL AGGRESSIVELY BOND TO CONCRETE AND METAL STRUCTURES. 12. FOR PIPE LARGER THAN 15 INCHES IN DIAMETER, THE MINIMUM INSIDE DIAMETER OF THE MANHOLE SHALL BE IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS BASED ON PIPE SIZE AND ANGLE BETWEEN INLET AND OUTLET PIPING. 13. 6' MINIMUM DIAMETER MANHOLE SHALL BE REQUIRED WHEN DEPTHS EXCEED 15' UNLESS OTHERWISE APPROVED BY PARTICIPATING UTILITY. 08/01/15 3/4" DIA. SS THREADED ROD (IF ADJUSTMENT RINGS ARE REQUIRED) PRECAST HOLE (TYP.) FLEXIBLE BOOT WITH STAINLESS STEEL BAND (TYP.) SECTION A-A STONE BASE (6" MIN. DEPTH) #57 OR EQUIVALENT SLOPE BENCH 1/4" PER 1'-0" PRECAST HOLE WITH FLEXIBLE BOOT & STAINLESS STEEL BAND MINIMUM SLOPE FOR SERVICE CONNECTION 4" DIA.=1/4" PER 1'-0" 6" DIA.=1/8" PER 1'-0" 1'-4" Max. MACHINED SURFACE 12" MAX 27 1/2" DIA 26 1/4" DIA 24" DIA 28 7/16" DIA 36" DIA NOTE 4 1 1/2" 5/8" INSTALLATION DETAIL FOR SLOPE ADJUSTMENT APPLY CONCRETE BONDING AGENT TO BOTTOM OF FRAME FORM AND FILL WITH NON-SHRINK GROUT (VIBRATE IN PLACE) OR USE MANHOLE ADJUSTMENT RINGS (1'-0" MAX. ADJUSTMENT) ADJUSTMENT NUT (TYP.)FLEXIBLE FORMS INSTALLATION DETAIL FOR ALL FRAMES AND COVERS ROD TO BE FIRMLY SECURED BY EPOXY ADJUSTMENT RING WHEN REQUIRED BUTYL MASTIC SECURE NUT CONE SECTION TOP OF CONE SECTION 3/4" STAINLESS STEEL THREADED ROD AND NUTS (4 TYP.) 3/4" STAINLESS STEEL THREADED ROD AND NUTS (4 TYP.) TOP OF CONE SECTION CONE SECTION 1. WATERTIGHT MANHOLE FRAME MODEL #1045Z BY EAST JORDAN IRON WORKS, INC. OR EQUIVALENT. 2. HDPE ADJUSTMENT RINGS SHALL MEET H-20 LOAD RATING, AND SHALL BE INTERLOCKING OR UTILIZE BUTYL MASTIC JOINT SEALANT BETWEEN EACH RING TO FORM A WATERTIGHT JOINT. 3. CONCRETE ADJUSTMENT RINGS SHALL MEET H-20 LOAD RATING AND UTILIZE BUTYL MASTIC JOINT SEALANT BETWEEN EACH RING AND FRAME AN COVER TO FORM A WATERTIGHT JOINT. 4. FRAME HEIGHT SHALL BE 7" FOR BURIED LOCATIONS AND 4" FOR EXPOSED LOCATIONS. 01/01/14 FRAME SECTION 3 1/8" 1/2" 26" DIA. 13/16" 1 1/2" 1/2" 1 3/8" 3 13/16" 9/16" 1 5/8" I R G I N I AV W E S T E R N 1" STANDARD MANHOLE COVER MODEL #1040AGS BY EAST JORDAN IRON WORKS, INC OR EQUIVALENT. 1. BOLT-DOWN MANHOLE COVER MODEL #1040ACLGS BY EAST JORDAN IRON WORKS, INC OR EQUIVALENT. 2. HEX HEAD BOLTS (6-SIDED) SHALL BE USED. 3. BOLT-DOWN MANHOLE COVERS SHALL BE USED WHEN SHOWN ON PLANS OR AS DIRECTED BY THE PARTICIPATING UTILITY. MACHINED SURFACE SA N I T A R Y SEW E R E A S T JORDAN IRON WORKS MADE I N US A 01/01/14 1 1/2" 1/4" DIA. NEOPRENE GASKET STOP LUGS FOR CAM 2" LETTERS (RECESSED FLUSH)NON-SLIP TEXTURE (2) CLOSED PICKHOLES (2) PICKBARS SEE DETAIL BELOW 2" LETTERS (RECESSED FLUSH) 25" DIA. O.D. OF GKT GROOVE 1/4" DIA. NEOPRENE GASKET .63" DIA. STAINLESS STEEL ROD 22 13/16" DIA. SECTION VIEW PICKBAR DETAIL BOTTOM VIEW OF COVER FOR PARTICIPATING UTILITIES OTHER THAN THE WVWA, GENERIC NON-LOGO MANHOLE COVERS LABELED "SEWER" SHALL BE SUBSTITUTED 21 PROJECT NO. REVISIONS SCALE DATE CHECKED BY DESIGNED BY DRAWN BY www.balzer.cc Roanoke / Richmond New River Valley / Staunton Harrisonburg / Lynchburg PLANNERS / ARCHITECTS ENGINEERS / SURVEYORS J: \ 2 0 \ 0 0 \ 0 4 \ 0 4 2 0 0 0 5 6 . 0 0 S I M M S F A R M S U B D I V I S I O N P H A S E 1 \ C I V I L \ d w g \ 0 4 2 0 0 0 5 6 . 0 0 C i v i l B a s e 2 0 2 1 - 8 - 6 R e v i s e d S W M . d w g P L O T T E D : F r i O c t 1 5 1 5 : 4 5 : 3 7 2 0 2 1 1208 Corporate Circle Roanoke, VA 24018 540.772.9580 KAM CPB BTC 1/25/2021 N/A SI M M S F A R M S E C T I O N 2 WE S T E R N V I R G I N I A R E G I O N A L D E T A I L S I I UP L A N D D R CI T Y O F S A L E M , V I R G I N I A C9.3 04200056.00 6/7/2021 9/1/2021 10/7/2021 10/15/2021 15" 1. SETTER TO BE A.Y. McDONALD 720-215WDDD33, FORD VBHH72-15W-11-33 OR APPROVED EQUAL. 2. SADDLES MUST BE USED WITH ALL PLASTIC & DUCTILE IRON PIPE. SERVICE SADDLES SHALL BE USED IN ACCORDANCE WITH WATER DISTRIBUTION PIPING SPECIFICATION. SERVICE SADDLES FOR PLASTIC PIPE SHALL BE: POWERSEAL 3417, OR 3412AS, ROMAC 202S, OR 306, OR FORD METER FS202 OR FS303. FOR DUCTILE IRON PIPE USE THE ABOVE OR POWERSEAL 3413, ROMAC 202 OR FORD METER F202. 3. METER BOX SHALL BE CARSON/MID-STATES PLASTICS, INC. PLASTIC BOX WITH FORD "A" DOMESTIC SERIES FRAME WITH A NICOR DOMESTIC 12.25 CX LID WITH SENSUS RECESS AND WVWA LOGO, ADS CORRUGATED HDPE BOX WITH FORD "A" DOMESTIC SERIES FRAME WITH A NICOR DOMESTIC 12.25 CX LID WITH SENSUS RECESS AND WVWA LOGO OR APPROVED EQUAL. METER BOX SHALL NOT BE PLACED IN AREAS SUBJECT TO VEHICULAR TRAFFIC. IF TRAFFIC BEARING BOX IS REQUIRED, DESIGN ENGINEER SHALL CONSULT WITH PARTICIPATING UTILITY TO DETERMINE SITE SPECIFIC REQUIREMENTS. 4. CORPORATION STOP SHALL BE FORD FB1000-4-G-NL, MUELLER B-25008 OR APPROVED EQUAL. 5. SERVICE SHALL BE "K" TYPE COPPER, OR COPPER TUBE SIZE POLYETHYLENE (PE) 4710, SODR-9 (200 psi). 6. WHENEVER SIDEWALK EXISTS OR IS PROPOSED, MODIFY METER LOCATION AS DIRECTED. FINAL GRADE 1" SERVICE 1" CORPORATION STOP WITH CTS COMPRESSION CONNECTION SEE NOTE #4 3/4" DIA. x 6' PIG TAIL TO BE CAPPED & MARKED OR STAKED METER SETTER & BOX TO BE SET AT FINAL GRADE OF SITE DUAL CHECK VALVE LOCKABLE SHUTOFF TRACER WIRE SEE GENERAL DETAIL 15" RIGHT-OF-WAY EASEMENT LINE PRIVATE PROPERTY SADDLE & STOP 6" STONE VDOT 57 METER BY PARTICIPATING UTILITY VARIES 18" DIA.12"-18" 1" SERVICE 30o- 45o WA T E R M A I N 09/07/17 1. TAPPING SLEEVE SHALL BE POWERSEAL MODEL 3490 TYPE 304 STAINLESS STEEL WITH CARBON STEEL FLANGE, ROMAC'S MODEL SST III, FORD MODEL FTSS WITH CARBON STEEL FLANGE OR APPROVED EQUIVALENT. SLEEVE SHALL BE RATED AT 100 PSI OVER WORKING PRESSURE AND MUST HAVE A TEST PLUG. 2. TAPPING VALVE SHALL BE AVK RESILIENT SEATED GATE VALVE SERIES 25 MJFL, MUELLER T-2360 RESILIENT WEDGE TAPPING VALVE WITH MJFL, OR AFC SERIES 2500 RESILIENT WEDGE TAPPING VALVE WITH MJFL. VALVE SHALL BE RATED AT 250 PSI. 3. TAPPING SLEEVE AND VALVE SHALL BE FULL PORT TO ACCEPT FULL SIZE SHELL CUTTER. 4. STEEL FLANGE SHALL MEET AWWA C207. 5. SIZE-ON-SIZE TAPPING NOT ALLOWED UNLESS APPROVED BY PARTICIPATING UTILITY. GROUND BAR SEE GENERAL DETAIL 2" BLOW OFF PRECAST WATER VALVE VAULT OR PRECAST MANHOLE SECTION(S) WHEN DEPTH EXCEEDS 5' TRACER & GROUND WIRES SEE GENERAL DETAIL 6" MINIMUM VDOT 57 TAPPED RESTRAINED M.J. PLUGMAIN LINE VALVE (SEE WATER LINE VALVE & VAULT DETAIL) 36' MIN. EXTENSION 12"-18" PAVEMENT ADJUSTMENT RING (WHEN REQUIRED) FINISHED GRADE 12" MAX. VERTICAL CENTERLINE OF VAULT CAPITOL FOUNDRY MH 2001 NON-WATERTIGHT FRAME & COVER LABELED "WATER" 2" THREADED NIPPLE WITH FINGER TIGHT CAP DRILL 1/4" DIA. HOLE IN CAP 2" CLEARANCE FROM TOP OF PIPE TO BOTTOM OF VAULT CUT-OUT WATER MAIN "STREET EL" 01/01/14 CONTRACTOR TO EXPOSE & CLEAN PIPE IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS GROUND ROD SEE GENERAL DETAIL 1. THE 2" PIPING AND "STREET EL" SHALL BE LEAD FREE BRASS OR DUCTILE IRON. 2. PIPE JOINTS SHALL BE RESTRAINED BEFORE GATE VALVE IN ACCORDANCE WITH DISTANCE SHOWN IN THE "MINIMUM THRUST RESTRAINT OF PIPE JOINTS DESIGN LENGTHS" DETAIL FOR VALVE / PLUG. PIPE JOINTS BETWEEN GATE VALVE AND BLOWOFF SHALL ALSO BE RESTRAINED. 01/01/14 1. PUBLIC HYDRANTS SHALL BE PAINTED SILVER WITH AN OIL-BASED PAINT. PRIVATE HYDRANTS SHALL ALSO BE PAINTED SILVER WITH AN OIL-BASED PAINT UNLESS OTHERWISE SPECIFIED BY THE JURISDICTIONAL FIRE MARSHALL. 2. FIRE HYDRANT SHALL BE INSTALLED 2' MIN. AND 4' MAX. FROM BACK OF CURB OR 6' MIN. AND 12' MAX. FROM EDGE OF PAVEMENT WHEN CURB IS NOT PRESENT. FIRE HYDRANT TO BE INSTALLED WITHIN RIGHT-OF-WAY OR EASEMENT LINE. 3. AREA AROUND HYDRANT AT A RADIUS OF 4' TO BE LEVEL AND UNOBSTRUCTED. 4. WATERPROOF BAGS OR OUT OF SERVICE RINGS SHALL BE PLACED OVER ALL NEWLY INSTALLED FIRE HYDRANTS. 5. HYDRANT ASSEMBLIES SHALL BE RODDED AND RESTRAINED WITH APPROVED M.J. GLAND RESTRAINTS. HIGH PRESSURE (OVER 150 PSI) ALSO REQUIRES CONCRETE THRUST BLOCKS AS SHOWN BELOW. 6. IF DURING CONSTRUCTION THE SEASONAL WATER LEVEL IS NOTED TO BE ABOVE THE DRAIN OUTLETS OF THE PROPOSED HYDRANT. THE PARTICIPATING UTILITY WILL BE NOTIFIED IMMEDIATELY SO THAT THE HYDRANT CAN BE RELOCATED TO A SUITABLE LOCATION, OMITTED, OR THE DRAIN HOLE PLUGGED. 7. TWO WRAPS OF TRACER WIRE SHALL BE WRAPPED AROUND BASE OF HYDRANT. 8. APPROVED MODELS - AVK MODEL 2780, AFC MODEL B-84-B-5, MUELLER CENTURION A423, KENNEDY K81D OR EQUIVALENT. 9. WHERE HYDRANT LATERAL(S) IS APPROVED BY THE PARTICIPATING UTILITY TO BE LONGER IN LENGTH, MAKING THE CONTINUOUS SECTION OF PIPE ON EACH SIDE OF THE GATE VALVE UNFEASIBLE, RESTRAINED PIPE JOINTS SHALL BE INSTALLED BETWEEN THE TEE AND GATE VALVE IN LIEU OF RODDING. HOWEVER, A RODDED CONTINUOUS SECTION OF PIPE SHALL ALWAYS BE INSTALLED BETWEEN THE GATE VALVE AND HYDRANT. AVK MODEL 2780, AFC MODEL B-84-B-5, MUELLER CENTURION A423, KENNEDY K81D OR EQUIVALENT. 1' - 6 " T O 2 ' - 0 " AB O V E C U R B OR E D G E O F PA V E M E N T 2 - 2 1/2" NOZZLES FINISHED GRADE 1 - 4 1/2" PUMPER NOZZLE (FACING THE ROAD) VALVE BOX (W/ ADAPTOR) IF OUTSIDE PAVEMENT OR VALVE VAULT UNDER PAVEMENT STANDARD INSTALLATION INCLUDES FOSTER ADAPTER OR APPROVED EQUAL WATER MAIN CONCRETE THRUST BLOCK (IF REQUIRED) TEE - MAIN LINE SIZE x 6" TO VALVE AND HYDRANT M.J. FITTINGS SHALL NOT BE ENCASED IN CONCRETE APPROVED M.J. GLAND RESTRAINT (i.e. MEGALUGS, GRIP RINGS OR UNI-FLANGE) SHALL BE USED AT ALL M.J. FITTINGS TRACER WIRE SEE GENERAL DETAIL 3/4" DIA. "CORTEN" (NON-CORROSIVE) THREADED ROD AND NUTS CONCRETE BASE AND THRUST BLOCK (IF REQUIRED) AGAINST UNDISTURBED SOIL, CONCRETE SHALL NOT COVER HYDRANT DRAIN 0.5 CY CLEAN STONE VDOT #57 FOR DRAINAGE 02/10/15 VARIES (NO OBSTRUCTIONS) 2'X2'X4"CONCRETE PAD CONTINUOUSSECTION OF PIPE CONTINUOUSSECTION OF PIPE 3' M I N . C O V E R 1. ALL JOINTS SHALL BE RESTRAINED ON BOTH SIDES OF THE FITTING AND DOCUMENTED BY THE INSPECTOR FOR THE LENGTH SHOWN UNLESS OTHERWISE INDICATED. 2. RESTRAINED LENGTH SHOWN REFERS TO ANY DESIGNED OR POTENTIAL LINE STOP, INCLUDING ALL GATE VALVES. 3. RESTRAINED LENGTH SHOWN REFERS TO THE BRANCH LINE ONLY. THE CONTINUOUS PIPE LENGTH OF THE MAIN RUN SHALL BE A MINIMUM OF 10' ON EACH SIDE OF THE TEE. 4. RESTRAINED LENGTH SHOWN IS BASED ON REDUCING PIPE DIAMETER TO ONE SIZE SMALLER THAN PIPE LISTED (ANY OTHER DIAMETER REDUCTION WILL REQUIRE ADDITIONAL CALCULATIONS BEFORE INSTALLATION). RESTRAINED LENGTH SHOWN IS UPSTREAM ON THE LARGE SIDE OF THE REDUCER. 5.12" AND SMALLER DIAMETER: IF UNDER 150 PSI WORKING PRESSURE, RESTRAINED JOINT(S) ARE TO BE USED. IF EQUAL TO OR OVER 150 PSI WORKING PRESSURE, BOTH THRUST BLOCK(S) AND RESTRAINED JOINT(S) SHALL BE USED. LARGER THAN 12" DIAMETER: IF UNDER 100 PSI WORKING PRESSURE, RESTRAINED JOINT(S) ARE TO BE USED. IF EQUAL TO OR OVER 100 PSI WORKING PRESSURE, BOTH THRUST BLOCK(S) AND RESTRAINED JOINT(S) SHALL BE USED (UNLESS OTHERWISE APPROVED BY THE PARTICIPATING UTILITY). 6. FOR RESTRAINED JOINT PIPING REQUIREMENTS AT FITTING R.J. PVC AND R.J. DIP MAY BE USED INTERCHANGEABLY WITH APPROVAL FROM PARTICIPATING UTILITY. CONTRACTOR MUST PLAN ACCORDINGLY FOR THE DIFFERENCE IN PVC AND DIP BELL AND SPIGOT DIMENSIONS. FACTOR OF SAFETY = 1.5 02/10/15 12" MAX. VERTICAL ADJUSTMENT CAPITOL FOUNDRY MH 2001 NON-WATERTIGHT FRAME & COVER LABELED "WATER"PAVEMENT ADJUSTMENT RING GROUND BAR SEE GENERAL DETAIL PROPOSED VALVE 6" COMPACTED VDOT 57 WATER MAIN TRACER & GROUND WIRES SEE GENERAL DETAIL PRECAST WATER VALVE VAULT OR PRECAST MANHOLE SECTION(S) IF DEPTH EXCEEDS 5' 2" CLEARANCE FROM TOP OF PIPE TO BOTTOM OF VAULT CUT-OUT GROUND ROD SEE GENERAL DETAIL FILTER FABRIC 1. FILTER FABRIC TO BE INSTALLED BETWEEN BOTTOM OF PIPE AND STONE BEDDING. FABRIC TO EXTEND VERTICALLY A MINIMUM OF 6" FROM BOTTOM OF VAULT (FULL CIRCUMFERENCE). 46" 6" MIN (TYP.)32" 01/01/14 22